Ameriderm Laboratories, Ltd.
126 Pennsylvania Ave, Paterson, New Jersey, United States
FEI 3001452902
FDA has 2 inspections on file for Ameriderm Laboratories, Ltd. in Paterson, New Jersey (FEI 3001452902), from 2011 to 2013. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2011–2013
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Representative Samples Criteria
The number of containers to be sampled and amount of material taken from each container is not based upon appropriate criteria.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by rodents, birds insects, and other vermin.
Microbiological Contamination Exam
Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.
Show 7 more citations
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not justified.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components and drug product containers at all times in a manner to prevent contamination.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include assignment of responsibility, maintenance and cleaning schedules, description in sufficient detail of methods, equipment and materials used, and instructions for protection of clean equipment from contamination prior to use.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Written records kept in individual logs
Written records of major equipment cleaning and use are not included in individual equipment logs.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Show 7 more citations
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and instructions for protection of clean equipment from contamination prior to use.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred.
Written record of complaint to include findings, follow-up
Written records of investigation of a drug complaint do not include the findings of the investigation.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions and sampling and testing procedures.
In-process materials characteristics testing
In-process materials are not tested for identity, strength, and quality and approved or rejected by the quality control unit .
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Representative Samples
Representative samples are not taken of each shipment of each lot of components for testing or examination.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.100Written procedures; deviations2 of 2
- 21 CFR 211.165Testing and release for distribution2 of 2
- 21 CFR 211.182Equipment cleaning and use log2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.56Sanitation1 of 2
- 21 CFR 211.80General requirements1 of 2
Show all 14
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.198Complaint files1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3001452902 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3001452902. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.