Skip to content

Premier Cosmetic Laboratories Holding LLC

11910 Shiloh Rd Ste 142, Dallas, Texas, United States

FEI 3001451793

FDA has one inspection on file for Premier Cosmetic Laboratories Holding LLC in Dallas, Texas (FEI 3001451793). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 23 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2009
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance23 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Manufacturing Instructions and Specifications

      The master production and control records are deficient in that they do not include complete manufacturing, instructions, and procedures.

    2. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components, drug product containers, and closures at all times in a manner to prevent contamination.

    3. Calibration/Inspection/Checking not done

      Routine calibration and checking of equipment is not performed according to a written program designed to assure proper performance.

    4. Procedures Written and Followed

      Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written and followed.

    5. Written program not followed

      The written stability testing program is not followed.

    Show 18 more citations
    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Establish reliability of supplier's C of A

      Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.

    3. Cleaning/maintenance records not kept

      Records are not kept for the maintenance and cleaning of equipment.

    4. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    5. Review of representative number of batches

      Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    6. Status of Each Lot Identified

      Each lot of components, drug product containers, and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.

    7. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    8. Theoretical yield statement including percentages

      Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required.

    9. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    10. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number, code, and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    11. Labeling control records including specimens or copies

      Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.

    12. Quarantine of Rejected Components et. al.

      Rejected components, drug product containers, and closures are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.

    13. Supervisor Training/Education/Experience

      Individuals responsible for supervising the manufacture and packing of a drug product lack the education and training to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.

    14. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not reviewed and approved by the quality control unit.

    15. Inadequate number of personnel

      The number of qualified personnel is inadequate to supervise the manufacture, processing, and packing of each drug product.

    16. Quarantine Storage of Components

      Incoming components, drug product containers, and closures are not stored under quarantine until they have been tested or examined, as appropriate, and released.

    17. Description of containers, labels, et. al.

      Master production and control records lack a specimen or copy of each label and all other labeling and the signatures and dates entered by the person or persons responsible for the approval of labeling.

    18. Written Procedures Not Followed

      Written procedures are not followed for the testing of components.

Regulations FDA cited here

The 15 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

  • 21 CFR 211.25Personnel qualifications1 of 1
  • 21 CFR 211.63Equipment design, size, and location1 of 1
  • 21 CFR 211.67Equipment cleaning and maintenance1 of 1
  • 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
  • 21 CFR 211.80General requirements1 of 1
  • 21 CFR 211.82Receipt and storage of untested components, drug product containers, and closures1 of 1
  • 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
  • 21 CFR 211.89Rejected components, drug product containers, and closures1 of 1
Show all 15

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3001451793 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3001451793. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.