Center For Organ Recovery & Education
204 Sigma Dr, Pittsburgh, Pennsylvania, United States
FEI 3000719528
FDA has 7 inspections on file for Center For Organ Recovery & Education in Pittsburgh, Pennsylvania (FEI 3000719528), from 2009 to 2026. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 1271.160(a) and 21 CFR 1271.200(b).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 7, 2009–2026
- 0 OAI · 4 VAI · 3 NAI
- Inspections with 483 observations shown
- 4 of 7
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establishing a system
A tracking system that enables the tracking of HCT/Ps back and forth from the donor to the consignee or final disposition was not followed.
All core requirements covered in program
A quality program which addresses all of the core CGTP requirements, appropriate for the HCT/Ps manufactured and the manufacturing steps performed, has not been revised.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures inadequate
Procedures for the cleaning and maintenance of equipment were not followed.
Procedures re complaints
Procedures for the evaluation and documentation of complaints relating to core CGTP requirements were not followed.
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Release criteria verified, documented
Release criteria were not verified to have been met through a review of manufacturing and tracking records before HCT/Ps were made available for distribution.
Testing, screening, donor eligibility procedures
Procedures for all steps performed in the determining of donor eligibility of HCT/Ps were not established, defined, and implemented.
Ensuring appropriate core requirements followed
The quality program has not ensured that appropriate procedures related to core CGTP requirements were established and defined.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Controlling the labeling of HCT/Ps
Procedures to control the labeling of HCT/Ps were not established and followed.
Identification code
HCT/Ps were not assigned a distinct identification code that relates the HCT/Ps to the donor and all records related to the product.
Deviations--evaluation, cause, corrective action
Investigation of deviations related to core CGTP requirements did not include a review and evaluation of the deviation, efforts to determine the cause of the deviation, and corrective action(s) to address the deviation and prevent recurrence.
Program is appropriate for the HCT/Ps
A quality program appropriate for the HCT/Ps manufactured and manufacturing steps performed has not been established and followed.
Validation & approval--established procedures
Processes with results which could not be fully verified by inspection and tests, were not validated and approved according to established procedures.
Show 4 more citations
Procedures to meet core CTGP
Procedures appropriate to meet core CGTP requirements for all steps that you perform in the manufacture of HCT/Ps were not established and followed.
Monitoring--cross contamination, exposure to CD
Environmental conditions are not monitored when such conditions could cause contamination or cross contamination of HCT/Ps or equipment.
Procedures inadequate
Procedures for the maintenance of equipment were not followed.
Records maintained concurrently
Records were not maintained concurrently with the performance of each step.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 1271.160Establishment and maintenance of a quality program3 of 4
- 21 CFR 1271.200Equipment2 of 4
- 21 CFR 1271.290Tracking2 of 4
- 21 CFR 1271.47What procedures must I establish and maintain?1 of 4
- 21 CFR 1271.180Procedures1 of 4
- 21 CFR 1271.195Environmental control and monitoring1 of 4
- 21 CFR 1271.230Process validation1 of 4
- 21 CFR 1271.250Labeling controls1 of 4
Show all 11
- 21 CFR 1271.265Receipt, predistribution shipment, and distribution of an HCT/P1 of 4
- 21 CFR 1271.270Records1 of 4
- 21 CFR 1271.320Complaint file1 of 4
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3000719528 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3000719528. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.