Skip to content

Sioux Biochemical Inc

618 14th St Ne, Sioux Center, Iowa, United States

FEI 3000210500

FDA has 2 inspections on file for Sioux Biochemical Inc in Sioux Center, Iowa (FEI 3000210500), from 2010 to 2015. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 10 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

The most recent OAI inspection ended on May 19, 2010. No warning letter, court action or import refusal is filed under this FEI.

10 regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2010–2015
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.

    2. Review of representative number of batches

      Written procedures are not established and followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    4. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.

    5. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    Show 5 more citations
    1. Batch production and Batch Control Record Requirements

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, and packing.

    2. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    4. Signature and checking of records -- 2 persons

      The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.

    5. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing, directly supervising, and checking each significant step in the operation, for each batch of drug product produced.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices15 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Batch production and Batch Control Record Requirements

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, and packing.

    2. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    3. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number, code, and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    4. In-process materials specifications testing

      Examination and testing of samples is not done to assure that in-process materials conform to specifications.

    5. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing, directly supervising, and checking each significant step in the operation, for each batch of drug product produced.

    Show 10 more citations
    1. Review of representative number of batches

      Written procedures are not established and followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    2. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.

    3. Records of any sampling performed

      Batch production and control records do not include a record of any sampling performed, for each batch of drug product produced.

    4. Sample identification and other information

      Laboratory records do not include a description of the sample received for testing, the source or location from where the sample was obtained, the date the sample was taken, and the date the sample was received for testing.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    6. Signature and checking of records -- 2 persons

      The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.

    7. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    8. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.

    9. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    10. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 13

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3000210500 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3000210500. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.