FDA has 7 inspections on file for Catalent Ontario Limited in Windsor, Canada (FEI 3000118564), from 2009 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Jun 29, 2018. 2 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant, Catalent Pharma Solutions Inc. (D-U-N-S 796436181), has registered 21 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
7, 2009–2023
1 OAI · 3 VAI · 3 NAI
Inspections with 483 observations shown
3 of 7
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest FY2023
Warning letters
None on file
Import refusals
2 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Drug product reserve containers

      Drug product reserve samples are not stored in an immediate container-closure system that has essentially the same characteristics as the marketed product.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Specification description of sample/testing

      The specifications for components, drug product containers or closures and labeling are deficient in that they do not include a description of the sampling plan.

    2. Calibration/Inspection/Checking not done

      Routine calibration and inspection of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Bioresearch MonitoringCitations not published
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Component identity verification

      Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    3. Top/Middle/Bottom container sampling

      Sampling procedures are deficient regarding sampling components from the top, middle, and bottom of container.

    4. Component written specification

      Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Jan 20, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-5589Form 483· 1 of 2 sitesClosed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-3059Form 483· 1 of 4 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 5 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 7 inspections, with how many of them cited each.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3000118564, one row per refused product line.

2 refusals on 2026-09-08 · charged UNAPPROVED on 2 · no FDA sample analysis

FDA firm profile
  • 2026-09-08

    ACETAMINOPHEN (ANALGESIC)60LDC01

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-9633472-5/30003/1

  • 2026-09-08

    ACETAMINOPHEN (ANALGESIC)60LDC01

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-9633472-5/20003/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, analysis
Registration runs through
Dec 31, 2027
Registrant
Catalent Pharma Solutions Inc.D-U-N-S 796436181

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Catalent Pharma Solutions Inc. (D-U-N-S 796436181) as the registrant for this site and 21 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3000118564 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3000118564. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.