Lutheran Medical Center
150 55th St, Brooklyn, New York, United States
FEI 2471507
FDA has 3 inspections on file for Lutheran Medical Center in Brooklyn, New York (FEI 2471507), from 2010 to 2014. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 2 citations from this inspection: 1 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 1 under 21 CFR Part 820, the device quality system rules. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.194(a)(8), 21 CFR 606.100(b) and 21 CFR 606.160(a)(1).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2010–2014
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.
Lack/Inad procedure-Monitoring/Control of Validated Proces
Procedures for monitoring and control of process parameters for a validated process have not been established.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
QC procedures for supplies and reagents
The standard operating procedure fails to include a written description of the quality control procedures for supplies and reagents employed in blood collection.
Provide space for examination
Failure to provide adequate space for private and accurate examinations of individuals to determine their suitability as blood donors.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection and processing of blood and blood components for homologous transfusion are not always followed.
Schedules and procedures for equipment & calibration
The standard operating procedure fails to include a written description of schedules and procedures for equipment maintenance and calibration.
Person performing, test results, interpretation
Records fail to identify the person performing the work so as to provide a complete history of the work performed.
Show 1 more citation
Personnel dating/signing equipment log
The persons performing the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection of blood and blood components for homologous transfusion and further manufacturing purposes are not always followed.
Legibility and indelibility
Records are illegible and not indelible.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.194Laboratory records2 of 3
- 21 CFR 606.100Standard operating procedures2 of 3
- 21 CFR 606.160Records2 of 3
- 21 CFR 211.182Equipment cleaning and use log1 of 3
- 21 CFR 606.40Facilities1 of 3
- 21 CFR 820.75Process validation1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2471507 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2471507. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.