Geritrex Corporation
40 Commercial Ave, Middletown, New York, United States
FEI 2433753
FDA has 6 inspections on file for Geritrex Corporation in Middletown, New York (FEI 2433753), from 2009 to 2018. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.100(a).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 6, 2009–2018
- 0 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 5 of 6
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that conform to appropriate standards of identity, strength, quality and purity.
Label reconciliation discrepancies evaluation/investigation
Discrepancies found outside preset limits when reconciling the quantities of labeling issued, used and returned, were not investigated.
Protection from external factors
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Show 2 more citations
- 21 CFR 11
Electronic records
Electronic records are used, but they do not meet systems validation requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
In-process materials characteristics testing
In-process materials are not tested for purity and approved or rejected by the quality control unit after storage for long periods.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Unapproved and Misbranded Drugs4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures are written, and followed
Procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products are not written.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Written in-process control procedures
Written procedures are not established and followed that describe the in-process controls and tests to be conducted on appropriate samples of in-process materials of each batch.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure and followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining expiration dates.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.
Labeling and packaging improperly approved/released
Labeling and packaging materials not meeting the appropriate written specifications were approved and released for use.
Show 3 more citations
Calibration - at intervals, written program, remedial action
The calibration of instruments and recording devices is not done at suitable intervals with provisions for remedial action in the event accuracy and/or precision limits are not met.
Statement of methods and data
Laboratory records do not include a statement of each method used in the testing of a sample and the location of data that establish that the methods used in the testing of the sample meet proper standards of accuracy and reliability as applied to the product tested.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reprocessing/quality control unit
Reprocessing was performed without the review and approval of the quality control unit.
Washing and toilet facilities not provided and accessible
Washing and toilet facilities are not provided.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Regulations FDA cited here
The 15 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.100Written procedures; deviations3 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 5
- 21 CFR 211.160General requirements2 of 5
- 21 CFR 211.166Stability testing2 of 5
- 21 CFR 211.22Responsibilities of quality control unit1 of 5
- 21 CFR 211.52Washing and toilet facilities1 of 5
- 21 CFR 211.94Drug product containers and closures1 of 5
- 21 CFR 211.115Reprocessing1 of 5
Show all 15
- 21 CFR 211.122Materials examination and usage criteria1 of 5
- 21 CFR 211.125Labeling issuance1 of 5
- 21 CFR 211.130Packaging and labeling operations1 of 5
- 21 CFR 211.165Testing and release for distribution1 of 5
- 21 CFR 211.186Master production and control records1 of 5
- 21 CFR 211.192Production record review1 of 5
- 21 CFR 211.194Laboratory records1 of 5
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2433753 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2433753. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.