PharMEDium Services LLC

36 Stults Rd, Dayton, New Jersey, United States

FEI 2242985

FDA has 4 inspections on file for PharMEDium Services LLC in Dayton, New Jersey (FEI 2242985), from 2013 to 2017. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Oct 24, 2018 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below.

FDA issued a warning letter on (CDER). FDA's compliance record also lists one other action under this FEI: Injunction, . No import refusal is filed under this FEI.

Five regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
4, 2013–2017
4 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
4 of 4
4 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
4 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Released batches with failing tests

      OBSERVATION 1 Drug products failing to meet established specifications are not rejected. Specifically: a. On 03/11/17, during potency testing of 10 mEq Potassium Chloride in 0.9% Sodium Chloride 1000mL in Bags, lot 1706500800, a failing result was obtained (result 0.009 mEq/mL, specification (b) (4) j). Although the batch was given a rejection disposition, a shipment of this batch was distributed on 4/12/17. b. On 02/15/17, during potency testing of Potassium Phosphate in 0.9% Sodium Chloride 10mMol in 250mL Bags, lot 170440840, a failing result was obtained (result 0.05555 mMol/mL, specification ((b)(4) J ~b) (4) As part of the laboratory investigation, retesting was performed, and another failing result was obtained (result 0.05623 mMol/mL). The batch was released on 3/3/17, and shipped on 3/6/17.

    2. Observation 2

      Inadequate batch failure investigations

      OBSERVATION 2 There is a failure to thoroughly investigate any unexplained discrepancy or failure of a batch, regardless of whether the batch has been distributed, or a failure to expand an investigation to assess other batches that may also be impacted. The below deficiencies are in regard to aseptically filled sterile drug products that may be filled in syringes, bags, or cassettes: a. There have been approximately 8 confirmed failures for in-house sterility testing of finished sterile drug products since June, 2016 (a l (5f(4) is used; lots are sometimes r (b) (4 ); for testing, implicating approx. (b)(• ) lots). All of the associated batches that had been cor (4) for testing were rejected; however, the investigations do not routinely identify the contaminating microorganism, determine which of the I -(5)(4) I batches contributed to the failure (where applicable), or adequately assess other batches of drug product that were produced by the same personnel, in the same ISO-5 (b)(4) Laminar Flow Hoods, or used the same production equipment as the failed batches. For example: i. Investigation DNC-17-503 was raised 4/7/17, following failing sterility results for 7 (b) (4) batches of sterile injectable/infusion Magnesium Sulfate products, and all 7 batches were rejected. Although the production personnel responsible for these batches were assessed through observation for hand-washing technique, sterile gowning and gloving, cleaning and sanitization of the hood, sanitization of gloves and components, and various aspects of aseptic technique, no additional samples (other than those routinely collected) of other products, gowning/gloving, or increased environmental monitoring are collected to determine further potential impact. ii. Investigation DNC-17-1538 was raised 9/28/17, following failing sterility results for 4 (b) (4) batches of sterile injectable/infusion Potassium Chloride products, and all 4 batches were rejected. The same type of observational assessment described above, for various aspects of gowning/gloving, cleaning and sanitization, and aseptic technique, was performed for the associated production Technicians, but no heightened sampling of other products, gowning/gloving, or increased environmental monitoring was performed following the failure. iii. Investigation DNC-17-516 was raised 4/11/17, following failing sterility results for 2 (b) (4) batches of sterile injectable/infusion Diltiazem Hydrochloride products, and both batches were rejected. The same type of observational assessment described above, for various aspects of gowning/gloving, cleaning and sanitization, and aseptic technique, was performed for the associated production Technicians, but no heightened sampling of other products, gowning/gloving, or increased environmental monitoring was performed following the failure. iv. Laboratory Investigation INY-DA-17-33 was raised 4/20/17, following "questionable results" for sterility testing of a single lot of sterile infusion product Potassium Phosphate in 0.9% Sodium Chloride. The lot was rejected, but the investigation does not discuss why the result was interpreted as questionable or whether additional analytical training was necessary (reported that two Analysts disagreed on the result). Subsequent production investigation DNC-17-729 includes an observational assessment of the production Technician that made the batch, but does not include any heightened sampling of other products, gowning/gloving, or increased environmental monitoring following the failure, to assess potential further impact.

    Show observations 3 to 11
    1. Observation 3

      Inadequate cleaning/sporicidal procedures

      OBSERVATION 3 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically: Since June, 2016, there have been approximately 4 results of "TNTC [too numerous to count] colony forming units" for personnel glove monitoring samples of production Technicians collected during aseptic filling of sterile drug products in r (b)(4) I Laminar Flow Hoods (LFHs). Spore-forming microorganisms have been identified in each case. Other than routine environmental monitoring, there was no additional sampling of other surfaces (e.g., I (b)(4) I) or equipment to determine the potential source or route of glove contamination, whether cleaning and sanitization remain effective, and whether any further contamination persists. Additionally, there is no targeted assessment of other sterile drug products filled by the same Technicians or in the same )(• LFHs at the time of the failures. For example: i. "TNTC" was reported for left glove sample of Technician (b)(6) (collected 5/10/17), but there was no additional sampling and testing of sterile products filled by that Technician around the time of the failure, or of the same LFH or other equipment used, to determine if any contamination persisted. The sample plate was sent for organism identification on 5/25/17, finding "Bacillus Oceanisediminis," a "spore forming" organism, for which "the common source... identified is soil." During retesting and (b)(4) sets of investigational glove tests of the Technician on 5/15/17, a failing result of 2 CFU was found, but the "Corrective Action" section of the investigation states "The retest samples were acceptable. The retest samples contained zero colony forming units post incubation." The investigation was completed 7/14/17, approx. 2 months after the failure. ii. "TNTC" was reported for right glove sample of Technician (b)(6) (collected 8/11/17), but there was no additional sampling and testing of sterile products filled by that Technician around the time of the failure, or of the same LFH or other equipment used, to determine if any contamination persisted. The sample plate was sent for organism identification on 8/24/17, finding "Bacillus Licheniformis," a "spore forming" organism, for which "the common source... identified was soil." iii. "TNTC" was reported for left glove sample of Technician (b)(6) (collected 5/10/17), but there was no additional sampling and testing of sterile products filled by that Technician around the time of the failure, or of the same LFH or other equipment used, to determine if any contamination persisted. The investigation was completed 8/18/17, approx. 3 months after the failure was found on 5/16/17 and sent for organism identification on 5/19/17 (finding "Paenibacillus glucanolyticus," a "spore forming" organism). iv. "TNTC" was reported for left glove sample of Technician (b)(6) (collected 8/23/17), but there was no additional sampling and testing of sterile products filled by that Technician around the time of the failure, or of the same LFH or other equipment used, to determine if any contamination persisted. The sample plate was not sent for organism identification until 9/25/17, finding "Paenibacillus glucanolyticus," a "spore forming" organism. A sporicidal disinfectant is used on a I (b)(4) basis throughout the Clean Room and ISO-5 (b)(4) Laminar Flow Hoods and other surfaces. Although a disinfectant effectiveness study appears to have demonstrated a I (b)(4) I contact time was sufficient for the sporicide, the supplier recommends a r (b)(4) contact time. This contact time and sporicidal disinfection frequency have not been revisited since the findings described above, and trending of environmental and personnel monitoring does not target the isolation of spore-forming organisms such as those described in the above examples. The use of inadequate contact time for a sporicidal disinfectant is a repeat observation from

      Shortened here; the PDF has the full text.

    2. Observation 4

      Incomplete aseptic procedures

      OBSERVATION 4 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not fully in writing. SOP CPS-313, Aseptic Technique and Classified Area Management, identifies items such as bags of sterile diluent as low risk, due to their receipt from the supplier in a protective overwrap. These items are not required to be re-sanitized when they are transferred from the ISO-7 Clean Room to the ISO-5 (b) (4) Laminar-Flow Hoods (LFHs) for filling operations. Such items are I (b)(4) I in the unclassified preparation room and placed in r (b)(4), which are f (b) 4 ) I for staging in the ISO-7 Clean Room. Components may then be handled by personnel in the Clean Room for r (b)(4) I, in between which the Technician must handle and scan the paper batch record, which is not printed on sterile or low-particle shedding paper. On 12/6/17, we observed this practice during the preparation for filling of Sodium Phosphate added to 0.9% Sodium Chloride 250mL in Bags, lot 1733900820, in which several diluent bags were handled for scanning, then brought into the ISO-5 LFH. The bags were not (b)(4) I again r (b)(4), and only the injection ports of the bags were sanitized once inside the LFH. Additionally, on that same day, for the preparation for filling of Neostigmine Methylsulfate 1mg/mL in 5mL Syringes, lot 1733900750, we observed vials of drug product being (b)(4) 1 in ISO-7 at approx. 11:30 AM, after which the Technician handled the paper batch record, then the vials again. The vials were not transferred into the ISO-5 LFH until approximately 11:43 AM. Since June, 2016, there have been approximately 14 failing test units with microbial growth found during media fill simulations for demonstration of personnel aseptic technique or process validation. Of these 14 units, 8 have been found to be contaminated with various spore-forming Bacillus species, and identification on the remaining 6 contaminated units is pending (found 11/18/17). The media fill failures have been attributed to I (b)(4) (b) (4). Associated investigations have not identified any need for process improvement, specifically of SOP CPS-313. The use of paper batch records in the Clean Room is a repeat observation from the 4/18/16 to 5/26/16 inspection.

    3. Observation 5

      Non-representative sterility sampling

      OBSERVATION 5 Samples taken of drug products for determination of conformance to written specifications are not representative. Regardless of batch size, (b)(4) is pulled for sterility and endotoxin testing of all batches, unless the finished dosage unit contains less than (b) (4), in which coH• units are pulled. Since June, 2016, batches between approx. (b) (4) (b)(4) units in size have been produced. According to CPS-790, Using th (b) (4) for Sterility Testing of Compounded Sterile Preparations, a volume between (b) (4) is the minimum sample volume. For example: a. Phenylephrine Hydrochloride 100mcg/mL in 0.9% Sodium Chloride in 10mL Syringes, lot 1732600790, was produced on 11/24/17 and filled on (b) (4) syringe filling line (bH > this batch was compounded and filled into approx. (b) (4), which were then filled into approx. (b) (4) syringes. A (b) (4) was collected for microbiological testing, from which a sample of approx. (b)(4) was tested for sterility. b. Succinylcholine Chloride 20mg/mL in 5mL Syringes, lot 1732500010, was produced on 11/21/17 and filled on (b) (4) syringe filling line. This batch was (b) (4), which were then filled into approx. (b) (4) syringes. A r (b) (4) I was collected for microbiological testing, from which approx. l(b) (4) _ was tested for sterility. c. Ephedrine Sulfate 5mg/mL in 0.9% Sodium Chloride in 5mL Syringes, lot 1732400930, was produced on 11/21/17 and filled on r (b) (4) J filling line. This batch was compounded and filled into approx. r (b) (4) I, which were then filled into approx. (b) (4) syringes. A r (b)(4) J was collected for microbiological testing, from which approx (b) (4) 1 was tested for sterility.

    4. Observation 6

      Inadequate visual inspection procedures

      OBSERVATION 6 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality, and purity. Performance of 100% visual inspection of finished sterile drug products for particulate matter is not performed against a dark and light background for visualization of various types of particles throughout the filled container. CPS-788, Visual Inspection, has been established, describing specifically how to perform inspection for each finished unit for IV bags, cartridges, and syringes, but a planned deviation from the procedure has been written, as the light-box with dark and light background described in the procedure is not available for use. Additionally, although management explained that all r (b) (4) filled batches are visually inspected in the ISO-5 (b) (4) Laminar Flow Hood, this is not always documented in the batch record. For example, of 11 recent batch records reviewed (10/19/17 to 11/27/17), 8 did not have a record of visual inspection of finished units: • Potassium Chloride in 0.9% Sodium Chloride 10mEq in 150mL Bags, lot 1732800720, produced on 11/27/17 • 0.1% Ropivacaine Hydrochloride in 0.9% Sodium Chloride in 100mL Cassettes, lot 1729100170, produced on 10/19/17 • Oxytocin 30 Units added to 500mL 0.9% Sodium Chloride Injection USP Bags, lot 1729100340, produced on 10/19/17 • 0.0625% Bupivacaine Hydrochloride in 0.9% Sodium Chloride in 250mL Cassettes, lot 1729100180, produced on 10/19/17 • Potassium Chloride in 0.9% Sodium Chloride 40mEq in 500mL Bags, lot 1729100050, produced on 10/19/17 • Diltiazem Hydrochloride 100mg added to 0.9% Sodium Chloride in 150mL Bags, lot 1729100320, produced on 10/19/17 • Vancomycin Hydrochloride 750mg added to 0.9% Sodium Chloride in Bags, lot 1729100220, produced on 10/19/17 • 10mcg/mL Fentanyl Citrate in 0.9% Sodium Chloride in Bags, lot 1729100830, produced on 10/19/17 Although CPS-788, Section 7.6.2.1 requires it, there is no mechanism for visual inspection for particulate matter in syringes filled on 5 4 syringe filling line 5 4 Units go 5 4 b 4 after which they are only externally inspected for defects such as leaking or other damage. For example, no visual inspection is documented for the below batches filled on b 4 lines: • Phenylephrine Hydrochloride 100mcg/mL in 0.9% Sodium Chloride in 10mL Syringes, lot 1732100290, produced on 11/18/17 (b) (4) filled units were labeled) • Succinylcholine Chloride 20mg/mL in 5mL Syringes, lot 1731900870, produced on 11/16/17 (b) (4) filled units were labeled) The failure to perform visual inspection of finished sterile drug products against a dark and light background is a repeat observation from the 4/18/16 to 5/26/16 inspection.

    5. Observation 7

      Insufficient particulate monitoring

      OBSERVATION 7 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, environmental monitoring for non-viable particulates (air) is not performed at sufficient frequencies to represent routine production conditions within the ISO-7 Clean Room, each of the ISO-5 (b)(4) Laminar Flow Hoods (LFHs), or the D 4 syringe filling lines. This type of monitoring is performed (o)(4) using a 5 4 , during routine operations, with (5)(4) sample collections ( b 4 from: (b)(•> locations throughout the Clean Room, on th (bH > LFH t hood samples total), and j locations at each of the b 4 filling lines > < 1 filling line samples total). (t) f(4) I for l (5f(4) monitoring have been installed in each of the LFHs in late 2016, and are present on the r (b) (4) lines, but it is unclear if these have been qualified, as they are not presently being used. The insufficient frequency of non-viable air (particulate) monitoring in the ISO-5 LFHs and ISO-7 Clean Room is a repeat observation from the 4/18/16 to 5/26/16 inspection.

    6. Observation 8

      No electronic data review procedure

      OBSERVATION 8 Input to and output from the computer, related systems of formulas, or records or data are not checked for accuracy. a. There is currently no procedure to describe the review of analytical data used for release testing of finished drug products. There is no documented review of electronic raw data or audit trails, to determine, for example, whether product has undergone unauthorized retesting or whether data has been otherwise manipulated. Testing for potency, sterility, and endotoxin is performed on all finished product batches, and all of the testing equipment captures data electronically (e.g. I '(1:5)(4) 11 1:5)(4) J • (b) (4) (b)(4) (b)(4) (b)(4) r(bf(4) System for endotoxin analysis, and r (bf(4) , System). SOP CPS-728, Review of Batch Processing Documentation, does not describe any review of analytical data. b. Quality Control laboratory worksheets are issued from an electronic document control system, but are accessible to the analyst for unlimited printing, with no date/time-stamp or other issuance controls for reconciliation against other laboratory data. c. Electronic logs of Quality System reports or files are maintained on uncontrolled spreadsheets on a shared network drive, and there are no controlled paper logs. The electronic spreadsheets do not have an audit trail function to show if previously entered items have been altered or deleted. Logs for the following items are stored in this manner: Notice of Event (NOE) reports, Non-Conformance Reports (NCRs), Laboratory Out-Of-Limit or Out-Of-Specification (OOL/OOS) reports, Customer Complaint reports, and Corrective and Preventive Action (CAPA) reports.

    7. Observation 9

      Inadequate instrument calibration checks

      OBSERVATION 9 The calibration of instruments is not done at suitable intervals in accordance with an established written program. (b) (4) Check Procedure, does not require daily verification of upper and lower limits that bracket analytical material being measured. (b) (4) verification typically includes a single point. For example: a. Balance I (b) (4) is routinely verified with a single standard weight of (b) (4) before use. On 7/10/17, it was used to measure 16.0mg of a USP reference standard; and on 8/28/17, it was used to measure 8.0mg of a USP reference standard. b. Balance I (b) (4) I is routinely verified with a single standard weight of (b) (4) before use. On 10/12/17, it was used to measure 2.0 mg of a USP reference standard.

    8. Observation 10

      Missing in-process label specimens

      OBSERVATION 10 Packaging and labeling records do not include a specimen of all labels used. Specifically, examples of the labels applied directly to each finished dosage unit and secondary packaging are maintained in the batch production record, but a record of in-process labels that may be applied to r (b) (4) I or (b) (4) I (o) (-4) I is not maintained. For example: a. The batch record for 10mEq Potassium Chloride in 0.9% Sodium Chloride 1000mL in Bags, lot 1706500800, produced 3/7/17, contains a representative label applied to the finished product bags and the shipper cartons, but not the in-process labels that are applied to the (5)(4) I used in I (5 (4), or the ! (5)(4) I used i I b. The batch record for Potassium Phosphate in 0.9% Sodium Chloride 10mMol in 250mL Bags, lot 170440840, produced 2/14/17, contains a representative label applied to the finished product bags and shipper cartons, but not (b)(4) (b)(4) (b)(4) the in-process labels that are applied to the I used in r , or the f I c. The batch record for 0.1% Ropivacaine Hydrochloride in 0.9% Sodium Chloride in 100mL Cassettes, lot 1729100170, produced 10/19/17, contains a representative label applied to the finished cassettes and shipper cartons, but not the in-process labels that are applied to the I (b)(4) I used in (b)(4) or the (b)(4) I used in I (b)(4) I d. The batch record for Phenylephrine Hydrochloride 100mcg/mL in 0.9% Sodium Chloride in 10mL Syringes, lot 1732600790, produced 11/24/17, contains a representative label applied to the finished syringes and shipper cartons, but not the in-process labels that are applied to the ther (b) (4 ) I or the -I (b) (4 ) I

    9. Observation 11

      Required labeling information omitted

      OBSERVATION 11 The labels of your outsourcing facility's drug products do not include information required by Section 503(B)(a)(10)(A). Specifically: A. The date the drug was compounded. Examples of drug product labels that do not contain this information: • 4% Sodium Citrate (Preservative Free) 40mg per mL, 120mg per 3mL (in 5mL Syringes) • Potassium Chloride in 0.9% Sodium Chloride, 40mEq in 250mL (in Bags) • Diltiazem HCl 125mg in 125mL 0.9% Sodium Chloride Injection USP (in Bags) • Oxytocin 30 Units added to 500mL 0.9% Sodium Chloride Injection USP (in Bags) • Phenylephrine HCl 100mcg per mL, 1mg per 10mL, in 0.9% Sodium Chloride (in 10mL Syringes) • 0.2% Ropivacaine HCl in Sodium Chloride 0.9% (in Yellow Cassette Reservoirs) B. A list of active and inactive ingredients, identified by established name and the quantity or proportion of each ingredient [this information can be included on the container if there is insufficient space on the product label]. Examples of drug product labels that do not contain this information: • 4% Sodium Citrate (Preservative Free) 40mg per mL, 120mg per 3mL (in 5mL Syringes) • Potassium Chloride in 0.9% Sodium Chloride, 40mEq in 250mL (in Bags) • Diltiazem HCl 125mg in 125mL 0.9% Sodium Chloride Injection USP (in Bags) • Oxytocin 30 Units added to 500mL 0.9% Sodium Chloride Injection USP (in Bags) • Phenylephrine HCl 100mcg per mL, 1mg per 10mL, in 0.9% Sodium Chloride (in 10mL Syringes) • 0.2% Ropivacaine HCl in Sodium Chloride 0.9% (in Yellow Cassette Reservoirs) The failure to include the date of compounding and a list of inactive ingredients on drug product labeling is a repeat observation from the 4/18/16 to 5/26/16 inspection.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

    4. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.

    5. Components withheld from use pending release

      Each lot of components and drug product containers is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    Show 4 more citations
    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components , in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    3. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    4. Citation

      New and Unapproved Cite

  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Product flow through building is inadequate

      The flow of components, drug product containers, closures, in-process materials, and drug products though the building is not designed to prevent contamination.

    2. Labeling Control Records and Label Copies

      The batch production and control records are deficient in that they do not include specimen and copy of labeling.

    3. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing, processing, packing, and holding of drug products is not appropriate for the duties they perform.

    4. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    5. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    Show 4 more citations
    1. Defined areas of adequate size for operations

      The control systems necessary to prevent contamination or mix-ups are deficient.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    3. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    4. Training , Education , Experience overall

      Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the training required to perform their assigned functions.

  7. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written record of complaint to include findings, follow-up

      Written records of investigation of a drug complaint do not include the findings of the investigation.

    2. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

    3. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    4. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    5. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    Show 6 more citations
    1. Microbiological Contamination Exam

      Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    4. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, sampling, testing, and approval of closures.

    5. Establish reliability of supplier's C of A

      Establishment of the reliability of the container and closure supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.

    6. Reserve drug product sample quantity - all tests

      The reserve sample of drug product does not consist of at least twice the quantity necessary to perform all the required tests of drug product.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.

Show all 14

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • InjunctionCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2242985 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2242985. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.