Skip to content

Welch, Holme & Clark Co., Inc

7 Avenue L, Newark, New Jersey, United States

FEI 2211876DUNS 001793728

FDA has 3 inspections on file for Welch, Holme & Clark Co., Inc in Newark, New Jersey (FEI 2211876), from 2010 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: 21 CFR 211.25(a).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for analysis and repacking, through Dec 31, 2027. Its registrant is Welch, Holme & Clark Co.,Inc. (D-U-N-S 001793728).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2010–2024
0 OAI · 2 VAI · 1 NAI
Inspections with 483 observations shown
2 of 3
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest Feb 10, 2025
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    2. GMP Training Frequency

      GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    3. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Packaging line inspection before use

      Inspection of the packaging facilities immediately before use is not done to assure that all drug products have been removed from previous operations.

    2. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.

    4. Examination of packaging and labeling

      Examination of packaging and labeling materials for suitability and correctness before packaging operations is not performed and not documented in the batch production records.

    5. Testing in same container - closure system

      The written stability program does not assure testing of the drug product in the same container-closure system as that in which the drug product is marketed.

    Show 8 more citations
    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date.

    3. Determination not to conduct investigation of complaint

      The written record did not include the reason an investigation was found not to be necessary when an investigation into unexplained discrepancies and the failure of a batch or any of its components to meet specifications was not conducted.

    4. Drug product reserve containers

      Drug product reserve samples are not stored in the same immediate container-closure system as the marketed product.

    5. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of packaging of the drug product.

    6. Sample size - test intervals

      The written stability program for drug products does not include test intervals based on statistical criteria for each attribute examined to assure valid estimates of stability.

    7. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.

    8. Test methods

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been documented.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Feb 10, 2025. Each one asked for a Form 483.

  • Inspection ending Jul 10, 2024VAI

    2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Feb 10, 2025FDA-FOIA-2025-1300Form 483· 1 of 2 sitesClosed
    2. Oct 10, 2024FDA-FOIA-2024-9017Form 483· 1 of 5 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 11

FDA drug establishment registration

FDA registration search
Registered operations
Analysis, repacking
Registration runs through
Dec 31, 2027
Registrant
Welch, Holme & Clark Co.,Inc.D-U-N-S 001793728

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2211876 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2211876. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.