Skip to content

McGuff Pharmaceuticals, Inc.

2921 W Macarthur Blvd Ste 141, Santa Ana, California, United States

FEI 2022073DUNS 116764634

FDA has 11 inspections on file for McGuff Pharmaceuticals, Inc. in Santa Ana, California (FEI 2022073), from 2010 to 2025. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.

FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.113(b) and 21 CFR 211.192.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is McGuff Pharmaceuticals Incorporated (D-U-N-S 116764634).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
11, 2010–2025
2 OAI · 4 VAI · 5 NAI
Inspections with 483 observations shown
4 of 11
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
3 requests, latest Jul 31, 2025
Warning letters
· CDER ↗
2 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies.

    2. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.

  2. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Flow of personnel and materials, facility

      Your facility was designed and/or operated in a way that permits poor flow of materials.

    2. FDCA 501(a)(2)(A)

      Unsealed HEPA filter, perimeter

      HEPA filters were not sealed around each perimeter to the support frame.

    3. FDCA 501(a)(2)(A)

      Inadequate sporicidal agents, cleanroom and ISO 5 area

      The use of sporicidal agents in the ISO 5 classified aseptic processing area was inadequate and infrequent.

    4. FDCA 501(a)(2)(A)

      Hazardous drugs, prevention of cross-contamination

      You produced hazardous drugs without providing adequate cleaning of work surfaces and cleaning of utensils to prevent cross-contamination.

    5. FDCA 501(a)(2)(A)

      First pass air blockage, open unit with sterile product

      Personnel conducted aseptic manipulations in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.

    Show 2 more citations
    1. FDCA 501(a)(2)(A)

      Use of non-pharmaceutical grade components

      You used a non-pharmaceutical grade component in the formulation of a drug product.

    2. FDCA 501(a)(2)(A)

      Disinfecting materials, aseptic processing area

      Materials or supplies were not disinfected prior to entering the aseptic processing areas.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Defined areas of adequate size for operations

      The separate or defined areas necessary to prevent contamination or mix-ups are deficient.

    3. Calibration/Inspection/Checking not done

      Routine inspection and checking of electronic equipment is not performed according to a written program designed to assure proper performance.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    5. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    Show 2 more citations
    1. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.

    2. Items to cover on annual reviews

      Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls and returned or salvaged drug products.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    2. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  11. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Jul 31, 2025. Each one asked for a Form 483.

  • Inspection ending Apr 28, 2025OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 31, 2025FDA-FOIA-2025-9261Form 483Closed
  • Inspection ending Jan 26, 2024

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Aug 1, 2024FDA-FOIA-2024-6703Form 483Closed
  • Inspection ending Nov 22, 2019VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Dec 8, 2023FDA-FOIA-2023-10961Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 11 inspections, with how many of them cited each.

Show all 11

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
McGuff Pharmaceuticals IncorporatedD-U-N-S 116764634

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2022073 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2022073. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.