Park Avenue Compounding
3662 Park Ave Ste 140, Saint Louis, MO, United States
FEI 1972829
FDA has 6 inspections on file for Park Avenue Compounding in Saint Louis, MO (FEI 1972829), from 2009 to 2025. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.
The most recent OAI inspection ended on Feb 8, 2024. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 6, 2009–2025
- 3 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 6
- 3 posted 483s not matched to an inspection
- Requested under FOIA
- 2 requests, latest May 4, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetOutsourcing Facility · CDERPosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic process validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. Media fills completed by compounding operators are not representative of your firm's largest batch size. 1. Your firm's media fill process is designed with a batch size of [illegible] units, while your firm's largest batch size produced and distributed from this facility is [illegible] units. Your firm has not provided sufficient scientific justification for the discrepancy in units produced in the media fill process. 2. Your firm's media fill process is designed with a batch size of [illegible]; firm's largest batch size produced and distributed from this facility is [illegible]. Your firm has not provided sufficient scientific justification for the discrepancy in units produced in the media fill process. B. Your firm's Media Fill records document the destruction of media fill units without adequate scientific justification. For example, but not limited to: With media fill "Process" Lot# [illegible], Qty [illegible] units your firm documented manipulating and discarding 35 units. Your firm does not have clear and specific written procedures describing interventions in which media units may be removed prior to incubation. The table below outlines several batches for which your firm discarded media units:
- Observation 2
Deficient cleaning/disinfection practices
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, on 9/19/2025, during your firm's "Terminal Cleaning" of the ISO-7 classified buffer rooms, completed by your firm's contracted vendor, we observed the following deficiencies: A. Cleaning technician used their gloved hands to adjust their sterile boot, exposing their skin to ISO 7 Buffer Room (Room 151). B. Cleaning technician in Buffer Room (Room 151) was observed kneeling on the ISO 7 floor with their knees to clean the wheels of a [illegible] cart, then continue cleaning without changing their sterile coverall and sterile boots. C. Cleaning technician in Buffer Room (Room 149) was observed sitting on the ISO 7 floor to clean the bottom of the ISO 5 LAFH, then continue cleaning without changing their sterile coverall and sterile boots.
Show observations 3 to 8
- Observation 3
Compromised airflow and risk assessment
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, your firm's June 2025 airflow evaluation (smoke studies) of the ISO-5 classified area where aseptic operations are performed shows unidirectional airflow is compromised and eddies/turbulence was observed under dynamic conditions. For example, but not limited to: A. Timestamp: at approximately [illegible]. During critical manipulations in your aseptic operations, your aseptic operator was observed leaning against the workbench, which resulted in eddies/turbulent air hitting their chest and re-entering the ISO 5 air potentially compromising the ISO 5 air. In addition, your firm does not perform personnel monitoring (PM) of each gowning sampling location (hood, chest, right forearm, left forearm) after each batch produced; instead these locations are rotated for each batch. For example, PM of the chest is taken every [illegible] batch produced. However, your firm has not performed a risk assessment justifying this statistical criteria for the sampling and testing to meet quality control criteria as a condition for their approval and release. B. Your firm's risk assessment (included in VAL-24-001) is inadequate as there are no smoke studies evaluating the airflow when moving materials used in aseptic operations from an unclassified area to an ISO-7 classified area; there is no justification for the environmental monitoring frequency (viable surface and viable air sampling) when [illegible]; there are no monitoring of pressure differentials ensuring air flows from higher to lower classification to prevent contamination. Your firm utilizes this [illegible], which connects non-classified Stockroom (room 132) to ISO 7 Stock Prep Room (room 147) for the movement of APIs and drug components. In addition, this risk assessment was conducted prior to your firm performing routine aseptic operations and your risk assessment identifies this as your firm's highest risk.
- Observation 4
Inadequate investigation and CAPA implementation
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. Your firm's deviations are inconsistent or inaccurate regarding reviews, risk assessment, root cause, immediate actions, historical reviews, and corrective and preventative actions (CAPA). For example, but not limited to: 1. QAL-25-018: (referenced in QAL-25-022 as a similar event) documents incorrect amounts of API injected into the "source bag" during the compounding of lot 20250303-71F6CA, Phenylephrine HCl 1000 mcg in 10 ml of NS Syringe. This error was potentially due to your aseptic operator using the incorrect syringe size when preparing your "source bags", not a repeater pump concern. [illegible] units were sent for testing and resulted in 0% potency. The risk assessment for this deviation was categorized as "medium". This lot was destroyed. i. CAPA-25-005 (referenced in QAL-25-018) addresses the incorrect syringe size and stated multiple corrective actions will be implemented in your master batch record for Phenylephrine, but references your master batch record for Oxytocin. In addition, during our review of your firm's batch records, all corrective actions were not implemented. Your current Master Batch Record (MBR) for Phenylephrine HCl 1000 mcg in 10 ml of NS Syringe does not include clear instructions or is omitted, for example, but not limited to: • Technicians must immediately stop compounding and notify a Pharmacist or QA upon identifying any issues. • Compounders will be responsible for removing [illegible] ml NS from source bag. • Vial to bag ratio adjustment: [illegible] ml syringe will be used per vial of phenylephrine. 2. Deviation, QAL-25-022: Documents a discrepancy in your firm's repeater pump count when reaching its set calibration point at [illegible] units during the production of lot 20250317-5A4CE3, Potassium Chloride 40 mEq in 0.9% NaCl, BUD 09/13/2025. [illegible] units were sent for testing and resulted in 0% potency. The risk assessment for this deviation was categorized as "high". This lot was reviewed and approved for distribution by a personnel with QA Manager access. i. CAPA-25-006 (referenced in QAL-25-022) addresses a calibration discrepancy identified with the repeater pump during processing of batch #20250317-5A4CE3 and stated three (3) batch record corrective actions are to be implemented for Potassium Chloride, but references your master batch record for Oxytocin. In addition, during our review of your firm's batch records, all corrective actions were not implemented. For example, but not limited to: • Mandatory compounding breaks B. Your firm has completed at least 8 deviations since 02/07/2025 in which particulate matter was associated with finished drug products that were distributed. CAPA-25-003 was initiated on 02/27/2025 to address at least seven (7) of these deviations. This CAPA states "between 01/13/2025 and 03/31/2025, during compounding and 100% visual inspections, pharmacists identified black/dark particulate matter in a single bag or syringe across multiple compounded lots. In each instance a second 100% visual inspection was performed by a different pharmacist, which found no additional particulates. In all cases, AQL assessments conducted by quality personnel confirmed the initial defects but found no additional issues or concerns across the lots". However, during our review of your firm's batch records associated with these lots, we noted the following discrepancies: [illegible table content]. In addition, this same CAPA states [vials] are to be replaced every [illegible] vials. However, this step is not outlined in any of your master batch records. Your aseptic operators continue to create deviations for particulate matter observed during visual inspections, which are linked to the same corrective action (CAPA-25-003) and your Quality Unit contin
Shortened here; the PDF has the full text.
- Observation 5
Insufficient visual inspection controls
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. Specifically, A. Your firm lacks scientific justification for visual inspection re-inspection procedures: 1. No documented rationale exists for performing additional 100% re-inspections following initial visual inspection failures. For example, but not limited to, the following batches underwent 100% re-inspection multiple times without justification: i. Potassium Chloride 40 mEq in 0.9% sodium chloride 270 mL Lot# 20250806-3BE96A BUD 02/02/2026 ii. Potassium Chloride 40 mEq in 0.9% sodium chloride 270 mL Lot# 20250722-8F0F44 BUD 01/18/2025 iii. Oxytocin 30 units in 0.9% sodium chloride 500 mL Lot# 20250708-85D2BE BUD: 09/06/2025 2. AQL (Acceptable Quality Level) re-inspections can be repeated up to [illegible] times. B. Your firm does not have written processes for multiple inspectors splitting a 100% visual inspection. Additionally, your firm has not conducted a risk assessment to evaluate the impact of this practice on inspection consistency and reliability, nor provided justification for this process. For example, but not limited to: Batch: Fentanyl Citrate 2 mcg/mL / Ropivacaine 0.2% in NS 150 mL, Lot# 20250429-SFE10A, Qty: [illegible] BUD 10/26/2025 Visual Inspector #1 Visual Inspector #2 Batch: Fentanyl Citrate 2 mcg/mL / Ropivacaine 0.2% in NS 150 mL, Lot# 20250507-01D93C, Qty: [illegible] BUD 11/04/2025 Visual Inspector #1 Visual Inspector #2 Batch: Phenylephrine Syringes 1000 mcg/10 mL, Lot# 20250411-0D5546, Qty: [illegible], BUD 10/08/2025 Visual Inspector #1 Visual Inspector #2 C. Your firm has not established and implemented a comprehensive defect library system. For example, but not limited to: 1. No documented defect library exists containing representative examples of acceptable and unacceptable product defects. 2. No established procedure exists for identifying, evaluating, and incorporating new defect types into the defect library. D. Your firm does not adequately control and document lighting conditions for visual inspections. For example, but not limited to: 1. Lux light intensity measurements are not documented for lights used during visual inspection operations. 2. Prior to 03/19/2025, lux light intensity was not measured for visual inspections completed on distributed drug products. As a result, approximately [illegible] units of drug products produced by your firm were released and distributed between 11/20/2024 and 09/11/2025 without verification and documentation of the lux light intensity used for visual inspection.
- Observation 6
Release without reviewing deviations/complaints
Drug product production and control records are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed. Specifically, a review of your firm's batch records found your firm released purportedly sterile drug products before reviewing the completed deviations or complaints associated with each batch. For example, but not limited to: A. Forty-three (43) days after this batch was approved for release, your firm's Quality Unit received the vendor's final investigation report for PCC-25-058, identifying the particulate matter by FTIR analysis, was found to be polyamide and cellulose, wood fiber. The investigation also stated the "particles were on the inside of the bags and would have been in contact with the solution." However, the batch record for Fentanyl Citrate 2 mcg/mL / Ropivacaine 0.2% in NS 150 mL, Lot 20250507-01D93C, BUD 11/04/2025, was approved for release without a thorough review of the following documents associated with this batch record, resulting in the release of [illegible] units. For example, multiple discrepancies related to particulate matter were found associated with this batch: 1. On 05/12/2025, the batch record, which was approved for release, documents visual inspection failed AQL for one (1) unit identified with a critical defect. However, multiple AQL failures were noted: (1) Product complaint, PCC-25-058: (a) First AQL fail: One (1) unit containing foreign particulate matter (b) Second AQL fail: Seven (7) additional units contained foreign particulates 2. Deviation, QAL-25-037: (i) AQL fail: Eight (8) units were found to contain visible foreign particulate matter (ii) Batch is to remain on QA hold pending the outcome of the vendor investigation for PCC-25-058. B. Deviation, QAL-25-002, was initiated on 01/21/2025, documenting your firm's Inventory personnel removed finished drug products from quarantine to be released, resulting in the distribution of [illegible] units of the incorrect lot of Potassium Chloride 40 mEq in 0.9% NaCl, prior to receiving release testing results.
- Observation 7
Unqualified transport tote materials
Equipment surfaces that contact components, in-process materials and drug products are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements. Specifically, your firm did not provide scientific justification or evaluate the material of construction for the [illegible] totes used to transport drug products and drug components used in sterile operations from an unclassified area to higher areas of classification (ISO-7). The totes that contain drug product and components come into direct contact with your firm's cleaning agents. However, your firm did not evaluate the degradation of the material when repeated exposure of your firm's cleaning agents occur over time to ensure [illegible].
- Observation 8
Inadequate electronic system controls
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A. Your firm utilizes a shared network that is accessible to all employees (operations, production, and quality) to access your firm's Quality Control Documents. For example, but not limited to: Environmental and Personnel Monitoring, Deviations, Complaints, Change Controls, Validation Protocols. Your non-quality personnel has unrestricted access to make changes to the following: 1. Uncontrolled excel spreadsheet used to track and trend your firm's environmental monitoring for classified areas. 2. Modify, delete, add data to complaint files. B. Your computerized software used for batch record release includes quality events associated with each batch record release (complaints, deviations, recalls, non-conformances). However, your firm does not have any written procedures for electronic reviews and has not performed any electronic audit trails to track the creation, modification, or deletion of such data to date. C. Your firm's control documents, such as environmental and personnel monitoring result forms, visual inspection result forms are accessible for unlimited printing, without any means of reconciliation (i.e. no date/time-stamp) by non-QC personnel. In addition, your firm's management stated your employee has reprinted at least one form instead of adhering to Good Documentation Practices.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release.
Adequate ventilation not provided
Adequate ventilation is not provided.
Sampling and testing procedures described
Written specifications for laboratory controls do not include a description of the sampling and testing procedures used.
Show 3 more citations
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Investigation scope did not include other batches
OBSERVATION 1 Investigationsof an unexplained discrepancy did not extend to other batches of the same drug product. Specifically, the scope of your initial investigation performed on 7/28/2017 for the (b)(4) process media fill failure did not extend to all sterile drug products produced via this process. Norepinephrine 8mg in 250mL of DSW bag is produced via the (b)(4) process. You only assessed Norepinephrine batches made post 7/12/2017. Some examples of Norepinephrine batches produced prior to 7/12/17 include: Lot# | Date Produced | Expiration Date 170703-017 7/3/2017 10/11/2017 170614-007 6/14/2017 9/12/2017 170606-006 6/6/2017 9/4/2017 110530-001 5/30/2017 8/28/2017
- Observation 2
Facility not maintained clean and sanitary
OBSERVATION 2 Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition. Specifically, on 10/24/2017 during the production of Phenylephrine HCl 1000 mcg in 0.9% Sodium Chloride 10 mL syringe Lot# 171024-014, I observed reddish-orange discoloration throughout (b)(4) ISO 5 LAFHs. In addition, a gray substance was observed behind the HEPA filter frame in the (b)(4) ISO 5 LAFH.
Show observations 3 to 6
- Observation 3
Inadequate environmental monitoring program
OBSERVATION 3 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, the firm's monitoring program for the ISO 5 hood in the IV room used to produce sterile drug products such as Phenylephrine HCl 1000 mcg in 0.9% Sodium Chloride 10 mL Lot# 171024-014 and Morphine Sulfate 50mg in 0.9% Sodium Chloride 50mL Lot# 171002-006 does not include: At least daily environmental monitoring for active viable air in the ISO 5 area during production. a. You only monitor viable air counts in-house with a settling plate during production. Active viable air monitoring is only conducted every (b)(4) by a contract service provider. b. At least daily surface monitoring of the work surface inside the ISO 5 LAFH during periods of production or at the end of operations. Surface monitoring is only performed (b)(4). c. Routine monitoring of personnel gowns during operations. Personnel gloved fingertip monitoring is only performed. d. Established alert and action limits for personnel gloved fingertips and settling plates.
- Observation 4
Released lots without stability data
OBSERVATION 4 Results of stability testing are not used in determining expiration dates. Specifically, you released 8 lots of Nicardipine 25mg in 250mL of NS from t:5 (4) to (t:5)(.14) without sufficient stability data to support the beyond use date (BUD) of 90 days. The following lots of Nicardipine 25mg in 250mL of NS were released: Lot# : Date Produced Expiration Date | Date Released 151007-4356 151029-4528 151103-4553 151110-4614 151217-4947 151230-5093 160114-5292 160126-5509
- Observation 5
Non-cleanable vinyl tape in ISO 5 hoods
OBSERVATION 5 Aseptic processing areas are deficient regarding systems for maintaining equipment used to control the aseptic conditions. Specifically, on 10/24/2017 during the production of Phenylephrine HCl 1000 mcg in 0.9% Sodium Chloride 10 mL syringe Lot# 171024-014, observed yellow and red vinyl type tape on the work surfaces inside the (b)(4) ISO 5 LAFHs, respectively. This does not appear easily cleanable or sanitizable. Furthermore, there are no procedures for changing of, cleaning or sanitizing of this vinyl type tape.
- Observation 6
No written procedure for label issuance
OBSERVATION 6 Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written. Specifically, you do not have a written procedure that explains the receipt, identification, storage, handling, sampling, and examination of finished product labels for sterile drug products such as Phenylephrine HCl 1000 mcg in 0.9% Sodium Chloride 10mL Lot# 171024-014 and Morphine Sulfate 50mg in 0.9% Sodium Chloride 50mL Lot# 171002-006.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on May 4, 2026. Each one asked for a Form 483.
Inspection ending Sep 23, 2025Not classified yet
2 requests. In the inspection history above. FDA has posted its Form 483.
- May 4, 2026FDA-FOIA-2026-4391Form 483· 1 of 5 sitesRecords released
- Nov 4, 2025FDA-FOIA-2025-12586Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 6 inspections.
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.28Personnel responsibilities1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1972829 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1972829. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.