Skip to content

Ivy Animal Health Inc

8857 Bond St, Overland Park, Kansas, United States

FEI 1910028DUNS 088106096

Company: Elanco US Inc. · Linked by exact D-U-N-S match (966985624) in FDA registration data

FDA has 7 inspections on file for Ivy Animal Health Inc in Overland Park, Kansas (FEI 1910028), from 2010 to 2023. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.160(b)(4) and 21 CFR 211.100(b).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2026. Its registrant, Elanco US Inc. (D-U-N-S 966985624), has registered 5 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
7, 2010–2023
0 OAI · 3 VAI · 4 NAI
Inspections with 483 observations shown
3 of 7
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  2. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  3. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  4. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity.

    2. Establishment of calibration procedures

      Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed.

  6. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    2. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not reviewed and approved by the quality control unit.

    3. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

  7. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written calibration procedures

      Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions.

    2. Containers sampled so as to prevent contamination

      Containers are not sampled in a manner designed to prevent contamination of their contents and other components.

    3. Weights and Measures of Components Used

      The batch production and control records are deficient in that they do not include weights and measures of components used in the process.

    4. Items to cover on annual reviews

      Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.

    5. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.

    Show 6 more citations
    1. Weight or measure of each component

      The master production and control records lack an accurate statement of the of each component.

    2. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    3. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not justified.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    5. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    6. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 7 inspections, with how many of them cited each.

Show all 11

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling
Registration runs through
Dec 31, 2026
Registrant
Elanco US Inc.D-U-N-S 966985624

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Elanco US Inc. (D-U-N-S 966985624) as the registrant for this site and the 5 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 1910028 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 1910028. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.