Penrose-St Francis Health Services Blood Bank
2222 N Nevada Ave, Colorado Springs, Colorado, United States
FEI 1771995
FDA has 5 inspections on file for Penrose-St Francis Health Services Blood Bank in Colorado Springs, Colorado (FEI 1771995), from 2009 to 2017. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 7 citations from this inspection. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
11 regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2009–2017
- 0 OAI · 5 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Provide proper equipment to meet requirements
Failure of equipment to perform in the manner for which it was designed so as to assure compliance with the official requirements prescribed in 21 CFR 606.
Record review prior to release
All records pertinent to a lot or unit were not reviewed before the release or distribution of a lot or unit of final product.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.
Arm preparation
The phlebotomy site is not prepared by a method that gives maximum assurance of a sterile container of Whole Blood.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection and processing of blood and blood components for allogeneic transfusion were not always maintained and followed.
Show 2 more citations
Unsuitable donation - release
Failure to prevent the release of unsuitable blood and blood components for transfusion.
Donor medical history
Failure to determine the suitability of a donation of blood and blood components based on whether the donor was free from factors that make the donor ineligible to donate.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Biological product deviation report
Failure to submit a biological product deviation report within 45 days from the date you acquired information suggesting that a reportable event occurred.
Distribution Recall System
The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
Blood & Blood Components
Failure to maintain temperatures during shipment of Whole Blood as required.
Written SOPs available for use by personnel
Failure to make available written procedures for use by personnel in the areas where the procedures are performed.
Person performing, test results, interpretation
Records fail to be as detailed as necessary so as to provide a complete history of the work performed.
Show 7 more citations
Obtaining consent in an appropriate manner
Failure to present the hazards and risks of plasmapheresis in such a manner that intelligent and informed consent can be given by the prospective Source Plasma donor.
Labeling of blood products unsuitable for transfusion
Failure to prominently label blood and blood components (except for recovered plasma) determined to be unsuitable for transfusion with "NOT FOR TRANSFUSION" and the reason the unit is considered unsuitable.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.
Provide space for examination
Failure to provide adequate space for private examinations of individuals to determine their suitability as blood donors.
Donor deferral record - each location
A record is not available from which unsuitable (deferred) donors may be identified so that products from such individuals will not be distributed.
Following manufacturer's instructions
Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection, processing, and distribution of blood and blood components for homologous transfusion and autologous transfusion are not always maintained and followed.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection, processing, storage, and distribution of blood and blood components for homologous transfusion are not always maintained and followed.
Blood & Blood Components
Failure to maintain temperatures during shipment of Whole Blood as required.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.
Controlling storage temperatures
The standard operating procedure fails to include a written description of the storage temperatures and methods of controlling storage temperatures for all blood products and reagents
Person performing, test results, interpretation
Records fail to identify the person performing the work and be as detailed as necessary so as to provide a complete history of the work performed.
Show 2 more citations
Qualifications of responsible personnel
The personnel responsible for the collection of blood or blood components are not adequate in training and experience, including professional training as necessary to assure competent performance of their assigned functions, and to ensure that the final product has the safety, purity, potency, identity and effectiveness it purports or is represented to possess.
Fresh Frozen Plasma - storage requirements
Failure to place plasma, separated from red blood cells and intended to be labeled Fresh Frozen Plasma, in a freezer within eight hours after phlebotomy at a temperature of -18 degrees Celsius or colder.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Donor deferral record - each location
A record is not available from which unsuitable (deferred) donors may be identified so that products from such individuals will not be distributed.
Qualifications of responsible personnel
The personnel responsible for the collection of blood or blood components are not adequate in training and experience, including professional training as necessary to assure competent performance of their assigned functions, and to ensure that the final product has the safety, purity, potency, identity and effectiveness it purports or is represented to possess.
Fresh Frozen Plasma - storage requirements
Failure to place plasma, separated from red blood cells and intended to be labeled Fresh Frozen Plasma, in a freezer within eight hours after phlebotomy at a temperature of -18 degrees Celsius or colder.
Biological product deviation report
Failure to submit a biological product deviation report within 45 days from the date you acquired information suggesting that a reportable event occurred.
Explanation of hazards
Failure to explain to the prospective Source Plasma donor the hazards of the plasmapheresis procedure.
Show 5 more citations
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the processing of blood and blood components for homologous transfusion and further manufacturing purposes are not always followed.
Person performing, test results, interpretation
Records fail to include dates of the various entries, show test results, show the expiration date assigned to specific products, and be as detailed as necessary so as to provide a complete history of the work performed.
Controlling storage temperatures
The standard operating procedure fails to include a written description of the storage temperatures and methods of controlling storage temperatures for all blood products and reagents
Labeling of blood products unsuitable for transfusion
Failure to prominently label blood and blood components (except for recovered plasma) determined to be unsuitable for transfusion with "NOT FOR TRANSFUSION" and the reason the unit is considered unsuitable.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Person performing, test results, interpretation
Records fail to identify the person performing the work and be as detailed as necessary so as to provide a complete history of the work performed.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection and processing of blood and blood components for homologous transfusion and autologous transfusion are not always followed.
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the processing of each unit of blood and blood components so that all steps can be clearly traced.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 606.100Standard operating procedures5 of 5
- 21 CFR 606.160Records4 of 5
- 21 CFR 600.15Temperatures during shipment2 of 5
- 21 CFR 606.20Personnel2 of 5
- 21 CFR 606.121Container label2 of 5
- 21 CFR 606.171Reporting of product deviations by licensed manufacturers, unlicensed registered blood establishments, and transfusion services2 of 5
- 21 CFR 640.612 of 5
- 21 CFR 640.34Processing2 of 5
Show all 14
- 21 CFR 211.150Distribution procedures1 of 5
- 21 CFR 606.40Facilities1 of 5
- 21 CFR 606.60Equipment1 of 5
- 21 CFR 606.65Supplies and reagents1 of 5
- 21 CFR 630.30Donation suitability requirements1 of 5
- 21 CFR 640.4Collection of the blood1 of 5
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1771995 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1771995. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.