The regulation
The current text of 21 CFR 640.34 from the Electronic Code of Federal Regulations.
§ 640.34 Processing.
(a) Plasma. Plasma shall be separated from the red blood cells and shall be stored at −18 °C or colder within 6 hours after transfer to the final container or within the timeframe specified in the directions for use for the blood collecting, processing, and storage system unless the product is to be stored as Liquid Plasma.
(b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted venipuncture with minimal damage to and minimal manipulation of the donor's tissue. The plasma must be separated from the red blood cells or collected by an apheresis procedure, and placed in a freezer within 8 hours or within the timeframe specified in the directions for use for the blood collecting, processing, and storage system, and stored at −18 °C or colder.
(c) Liquid Plasma. Liquid Plasma shall be separated from the red blood cells and shall be stored at a temperature of 1 to 6 °C within 4 hours after filling the final container or within the timeframe specified in the directions for use for the blood collecting, processing, and storage system.
(d) Platelet Rich Plasma. Platelet rich plasma shall be prepared from blood collected by a single uninterrupted venipuncture with minimal damage to and manipulation of the donor's tissue. The plasma shall be separated from the red blood cells by centrifugation within 4 hours after completion of the phlebotomy or within the timeframe specified in the directions for use for the blood collecting, processing, and storage system. The time and speed of the centrifugation shall have been shown to produce a product with at least 250,000 platelets per microliter. The plasma shall be stored at a temperature between 20 and 24 °C immediately after filling the final container. A gentle and continuous agitation of the product shall be maintained throughout the storage period, if stored at a temperature of 20 to 24 °C.
(e) Modifications of Plasma. It is possible to separate Platelets and/or Cryoprecipitated AHF from Plasma. When these components are to be separated, the plasma shall be collected as described in § 640.32 for Plasma.
(1) Platelets shall be separated as prescribed in subpart C of part 640, prior to freezing the plasma. The remaining plasma may be labeled as “Fresh Frozen Plasma,” if frozen within 6 hours after filling the final container or within the timeframe specified in the directions for use for the blood collecting, processing, and storage system.
(2) Cryoprecipitated AHF shall be removed as prescribed in subpart F of part 640. The remaining plasma shall be labeled “Plasma, Cryoprecipitate Reduced.”
(3) Plasma remaining after both Platelets and Cryoprecipitated AHF have been removed may be labeled “Plasma, Cryoprecipitate Reduced.”
(f) The final container. (1) The final container shall have no color added to the plastic and shall be transparent to permit visual inspection of the contents; any closure shall maintain a hermetic seal and prevent contamination of the contents.
(2) The final container material shall not interact with the contents, under the customary conditions of storage and use, in such a manner as to have an adverse effect upon the safety, purity, potency, and effectiveness of the product.
(3) Prior to filling, the final container shall be identified by number so as to relate it to the donor.
(g) The final product. (1) The final product shall be inspected immediately after separation of the plasma and shall not be issued for transfusion if there is (i) any abnormality in color or physical appearance, or (ii) any indication of contamination.
(2) With the exception of Platelet Rich Plasma and Liquid Plasma the final product shall be inspected for evidence of thawing or breakage at the time of issuance, however, the containers need not be stored in a manner that shows evidence of thawing if records of continuous monitoring of the storage temperature establish that the temperature remained at −18 °C or colder. If continuous monitoring of the product is not available, the final product shall be stored in a manner that will show evidence of thawing and shall not be issued if there is any evidence of thawing.
(3) No preservative shall be added to the final product.
21 CFR Part 640: Additional Standards for Human Blood and Blood Products, Subpart DRead on eCFR
Citations by year
Form 483 citations of 21 CFR 640.34 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 2 in 2015
| Year | Form 483 citations |
|---|---|
| 2011 | 1 |
| 2012 | 1 |
| 2015 | 2 |
| 2016 | 1 |
| 2019 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 6 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Fresh Frozen Plasma - storage requirements3 citations
- Final product - evidence of thawing1 citations
- Final product - inspection1 citations
- Liquid Plasma - storage requirements1 citations
Citation text
- “Failure to place plasma, separated from red blood cells and intended to be labeled Fresh Frozen Plasma, in a freezer within eight hours after phlebotomy at a temperature of -18 degrees Celsius or colder.”3 citations
- “Failure to inspect the final product immediately after separation of the plasma for and prevent issue for transfusion when there is abnormality in color, physical appearance, indications of contamination.”1 citations
- “Failure to store Liquid Plasma at a temperature of 1 to 6 degrees Celsius within 4 hours after filling the final container.”1 citations
- “Failure to store the final plasma product in a manner to show evidence of thawing.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 640.34, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Penrose-St Francis Health Services Blood Bank2012-11-19 · FEI 1771995Fresh Frozen Plasma - storage requirements
- Penrose-St Francis Health Services Blood Bank2011-03-03 · FEI 1771995Fresh Frozen Plasma - storage requirements
Often cited at the same inspection
Of the 6 inspections where FDA cited 21 CFR 640.34, the share where it also cited each of these sections.
- 21 CFR 606.100Standard operating procedures5 (83%)
- 21 CFR 606.160Records4 (67%)
- 21 CFR 606.20Personnel3 (50%)
- 21 CFR 640.21Eligibility of donors2 (33%)
- 21 CFR 600.12Records1 (17%)
- 21 CFR 600.15Temperatures during shipment1 (17%)
Ask FDAgent about 21 CFR 640.34
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 640.34; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.