Bio-Medical Pharmaceutical Manufacturing Corporation
4311 South Dr, Houston, Texas, United States
FEI 1650090DUNS 072186356
FDA has 4 inspections on file for Bio-Medical Pharmaceutical Manufacturing Corporation in Houston, Texas (FEI 1650090), from 2010 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Four FOIA requests have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.68(a).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, analysis, relabeling and repacking, through Dec 31, 2026. Its registrant is Bio-Medical Pharmaceutical Manufacturing Corporation (D-U-N-S 072186356).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2010–2025
- 1 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 4
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 4 requests, latest May 4, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Top/Middle/Bottom container sampling
Sampling procedures are deficient regarding sampling components from the top, middle, and bottom of container.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.
Calibration/Inspection/Checking not done
Routine calibration and inspection of equipment is not performed according to a written program designed to assure proper performance.
Show 4 more citations
Significant Step Accomplishment Dates
The batch production and control records are deficient in that they do not include dates of accomplished significant steps.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written calibration / inspection records not kept
Records of the calibration checks of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
GMP Training Frequency
GMP training is not conducted with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record of investigation incomplete
Written records of investigations into the failure of a batch or any of its components to meet specifications do not include the conclusions and follow-up.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on May 4, 2026. Each one asked for a Form 483.
Inspection ending Aug 29, 2025OAI
4 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Dec 8, 2025. FDAgent holds no copy that FDA posted.
- May 4, 2026FDA-FOIA-2026-4374Form 483· 1 of 5 sitesWithdrawn
- Feb 10, 2026FDA-FOIA-2026-1422Form 483· 1 of 4 sitesRecords released
- Dec 3, 2025FDA-FOIA-2025-13551Form 483Records released
- Oct 7, 2025FDA-FOIA-2025-11755Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance2 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.25Personnel qualifications1 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
- 21 CFR 211.142Warehousing procedures1 of 3
Show all 11
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 211.188Batch production and control records1 of 3
- 21 CFR 211.192Production record review1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis, relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Bio-Medical Pharmaceutical Manufacturing CorporationD-U-N-S 072186356
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1650090 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1650090. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.