Cosmetic Specialty Labs, Inc
210 Sw Texas Ave, Lawton, Oklahoma, United States
FEI 1622491
FDA has 4 inspections on file for Cosmetic Specialty Labs, Inc in Lawton, Oklahoma (FEI 1622491), from 2010 to 2023. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations II).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One FOIA request has asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2010–2023
- 1 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 4
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest May 29, 2024
- Warning letters
- · CDER · Division of Pharmaceutical Quality Operations II ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Show 8 more citations
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
Component written specification
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Individual inventory record
Records fail to include an individual inventory record of each component and reconciliation of the use of each component with sufficient information to allow determination of any associated batch or lot of drug product.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Identification of each component or in-process material
Batch production and control records do not include the specific identification of each batch of component used for each batch of drug product produced.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Certificates of Testing (Containers, Closures)
Certificates of testing of containers and closures are accepted in lieu of testing without a visual identification and establishing the reliability of the supplier's test results through appropriate validation of the test results at appropriate intervals.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and sampling plans designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Show 5 more citations
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container, and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on May 29, 2024. It asked for a Form 483.
Inspection ending Sep 20, 2023OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- May 29, 2024FDA-FOIA-2024-4733Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.165Testing and release for distribution2 of 2
- 21 CFR 211.182Equipment cleaning and use log2 of 2
- 21 CFR 211.184Component, drug product container, closure, and labeling records2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
Show all 13
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations II · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1622491 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1622491. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.