Universal Holdings I LLC
3501 W 48th Pl, Chicago, Illinois, United States
FEI 1410778
FDA has 3 inspections on file for Universal Holdings I LLC in Chicago, Illinois (FEI 1410778), from 2010 to 2014. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2010–2014
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Training--operations, GMPs, written procedures
Employees are not given training in written procedures required by current good manufacturing practice regulations.
Buildings not maintained in good state of repair
Buildings used in the manufacturing and holding of a drug product are not maintained in a good state of repair.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
Show 3 more citations
Written records kept in individual logs
Written records of major equipment cleaning and use are not included in individual equipment logs.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and processing of the drug product.
Cleaning SOPs/equipment protection
Procedures for the cleaning and maintenance of equipment are deficient regarding the protection of clean equipment from contamination prior to use.
Approval and review of procedures
Written procedures are not reviewed and approved by the quality control unit.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, and investigations conducted for each drug product.
Written sanitation procedures not followed
Written procedures for sanitation are not followed.
Show 10 more citations
Unlabeled filled containers controls
Filled drug product containers which are set aside and held in an unlabeled condition are not identified to preclude mislabeling of individual containers, lots or portions of lots.
Identity of major equipment and lines used
Batch production and control records do not include the identity of individual major equipment used for each batch of drug product produced.
Written records kept in individual logs
Written records of major equipment cleaning and use are not included in individual equipment logs.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Sampling/testing of labeling/packaging materials
Labeling and packaging materials are not examined upon receipt and before use in packaging and labeling of a drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.
Sampling/testing of in-process materials
The specifications for in-process materials are deficient in that they do not include a description of the sampling plan and testing procedures for in-process materials.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Floors, walls, ceiling surfaces
Aseptic processing areas are deficient in that floors are not smooth and/or hard surfaces that are easily cleanable.
Investigations made into any unexplained discrepancy
Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 1 more citation
Training , Education , Experience overall
Employees engaged in the manufacture of a drug product lack the education required to perform their assigned functions.
Regulations FDA cited here
The 19 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications3 of 3
- 21 CFR 211.58Maintenance2 of 3
- 21 CFR 211.160General requirements2 of 3
- 21 CFR 211.182Equipment cleaning and use log2 of 3
- 21 CFR 211.188Batch production and control records2 of 3
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.198Complaint files2 of 3
- 21 CFR 211.42Design and construction features1 of 3
Show all 19
- 21 CFR 211.56Sanitation1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.103Calculation of yield1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.122Materials examination and usage criteria1 of 3
- 21 CFR 211.125Labeling issuance1 of 3
- 21 CFR 211.130Packaging and labeling operations1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 211.180General requirements1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1410778 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1410778. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.