All Oxygen Refills, Inc.
4108 Nw 135th St, Opa Locka, Florida, United States
FEI 1032592DUNS 829356526
FDA has one inspection on file for All Oxygen Refills, Inc. in Opa Locka, Florida (FEI 1032592). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 18 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is All Oxygen Refills, Inc. (D-U-N-S 829356526).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2009
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance18 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lack of quality control unit
There is no quality control unit.
Quarantine - written procedures
Written procedures for the warehousing of drug products do not include quarantine of drug products before release by the quality control unit.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established.
Approval and review of procedures
Written procedures are not reviewed and approved by the quality control unit.
Calibration - at intervals, written program, remedial action
The calibration of instruments and gauges is not done at suitable intervals with provisions for remedial action in the event accuracy and/or precision limits are not met.
Show 13 more citations
In-process and laboratory control results
Batch production and control records do not include laboratory control results for each batch of drug product produced.
Procedures Written and Followed
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not independently checked, dated, and signed by a second person.
Cleaning/maintenance records not kept
Records are not kept for the maintenance, cleaning, and inspection of equipment.
Correct labels during finishing operations
Packaged and labeled products are not examined during finishing operations to provide assurance that containers and packages in the lot have the correct label.
Training--operations, GMPs, written procedures
Employees are not given training in written procedures required by current good manufacturing practice regulations.
Written sanitation procedures lacking
There is a lack of written procedures providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Training , Education , Experience overall
Employees engaged in the manufacture of a drug product lack the training required to perform their assigned functions.
Sampling/testing of labeling/packaging materials
Labeling and packaging materials are not examined upon receipt and before use in packaging and labeling of a drug product.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Recall facilitation
A system by which the distribution of each lot of drug product can be readily determined to facilitate its recall if necessary, has not been established.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.56Sanitation1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.122Materials examination and usage criteria1 of 1
- 21 CFR 211.125Labeling issuance1 of 1
- 21 CFR 211.134Drug product inspection1 of 1
Show all 14
- 21 CFR 211.142Warehousing procedures1 of 1
- 21 CFR 211.150Distribution procedures1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.186Master production and control records1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
- 21 CFR 211.198Complaint files1 of 1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- All Oxygen Refills, Inc.D-U-N-S 829356526
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1032592 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1032592. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.