Old 97 Company
4829 E 7th Ave, Tampa, Florida, United States
FEI 1010294
FDA has 2 inspections on file for Old 97 Company in Tampa, Florida (FEI 1010294), from 2009 to 2012. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 14 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.166(a).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2009–2012
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Theoretical yield statement including percentages
Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required.
Actual yield, % of theoretical yield
The batch production and control records do not include a statement of the actual yield and percentage of theoretical yield at appropriate stages of processing for each batch of drug product produced.
Inspection of packaging and labeling area
Batch production and control records do not include results of the inspection of the packaging and labeling area before and after use for each batch of drug product produced.
Description of containers, labels, et. al.
Master production and control records lack a description of the drug product containers, closures and packaging materials, a specimen or copy of each label and all other labeling, and the signatures and dates entered by the person or persons responsible for the approval of labeling.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Show 9 more citations
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Description of containers and closures
Batch production and control records do not include a description of drug product containers used for each batch of drug product produced.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing, control, instructions, sampling, testing, procedures, specifications, special notations, and precautions.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Inadequate number of personnel
The number of qualified personnel is inadequate to supervise the manufacture, processing, and packing of each drug product.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component.
Dates not included for each significant step
Batch production and control records do not include dates of each significant step in the manufacture, processing, packing, and holding of the batch for each batch of drug product produced.
Records of any sampling performed
Batch production and control records do not include a record of any sampling performed, for each batch of drug product produced.
Identification of Equipment and Lines
The batch production and control records are deficient in that they do not include the identity of major equipment and lines used.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Written records kept in individual logs
Written records of major equipment use are not included in individual equipment logs.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Show 2 more citations
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, and investigations conducted for each drug product.
No written record of investigation
Written records are not made of investigations into the failure of a batch or any of its components to meet specifications.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.166Stability testing2 of 2
- 21 CFR 211.188Batch production and control records2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.180General requirements1 of 2
Show all 11
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1010294 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1010294. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.