Gregory Pharmaceutical Holdings Inc. dba UPM Pharmaceuticals Inc.

501 5th St, Bristol, Tennessee, United States

FEI 1000208638DUNS 081301372

Company: UPM Pharmaceuticals · Linked by exact D-U-N-S match (081301372) in FDA registration data

FDA has 12 inspections on file for Gregory Pharmaceutical Holdings Inc. dba UPM Pharmaceuticals Inc. in Bristol, Tennessee (FEI 1000208638), from 2008 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

The most recent OAI inspection ended on Oct 27, 2008. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Gregory Pharmaceutical Holdings, Inc., dba UPM Pharmaceuticals (D-U-N-S 081301372).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
12, 2008–2024
1 OAI · 5 VAI · 6 NAI
Inspections with 483 observations shown
2 of 12
Form 483s posted by FDA
None held for this FEI
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

12 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Buildings not maintained in good state of repair

      Buildings used in the of a drug product are not maintained in a good state of repair.

    2. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.

    3. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    4. Following/documenting laboratory controls

      Established laboratory control mechanisms are not followed.

    5. Complaint Investigation/Follow-Up Findings

      Complaint records are deficient in that they do not include the findings of the investigation.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Written procedures followed

      Procedures for the preparation of master production and control records are not followed.

    3. Calibration/Inspection/Checking not done

      Routine inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

    4. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components at all times in a manner to prevent contamination.

  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  10. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  11. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  12. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 12 inspections, with how many of them cited each.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000208638, one row per refused product line.

1 refusal on 2024-01-12 · charged NOT LISTED on 1, FRNMFGREG on 1 · no FDA sample analysis

FDA firm profile
  • 2024-01-12

    POLYMYXIN B SULFATE (PEPTIDES)56FBK30

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Northern Border ImportsSCS-2000350-9/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Gregory Pharmaceutical Holdings, Inc., dba UPM PharmaceuticalsD-U-N-S 081301372

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000208638 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000208638. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.