Accupack Midwest Inc
1060 Meta Dr, Cincinnati, Ohio, United States
FEI 1000122754DUNS 139637433
FDA has 6 inspections on file for Accupack Midwest Inc in Cincinnati, Ohio (FEI 1000122754), from 2009 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations III). No court action or import refusal is filed under this FEI.
Nine regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, relabeling and repacking, through Dec 31, 2026. Its registrant is Accupack Midwest (D-U-N-S 139637433).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2009–2025
- 2 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest Mar 17, 2026
- Warning letters
- · CDER · Division of Pharmaceutical Quality Operations III ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the sampling, testing, approval and rejection of components.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred.
Lot or control number assigned
The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components and drug product containers at all times in a manner to prevent contamination.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Show 4 more citations
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the sampling, testing, approval and rejection of components.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance17 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written calibration / inspection records not kept
Records of the calibration checks of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Review of representative number of batches
Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Drug products-sampling procedures/specifications
Laboratory controls do not include a determination of conformance to appropriate specifications for drug products.
Show 12 more citations
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Acceptance of drug products
Determinations of conformance to appropriate written specifications for acceptance are deficient for drug products.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.
Accelerated stability studies
Accelerated stability studies, combined with basic stability information, used to support tentative expiration dates are not supported with ongoing full shelf life studies.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Components withheld from use pending release
Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Component Test Records
The component records do not include the results of tests or examinations performed.
Drug products-sampling procedures/specifications
Laboratory controls do not include a determination of conformance to appropriate specifications for drug products.
Lack of quality control unit
There is no quality control unit.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
SOPs not followed / documented
Written production and process control procedures are not documented at the time of performance.
Show 4 more citations
Calibration/Inspection/Checking not done
Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Mar 17, 2026. Each one asked for a Form 483.
Inspection ending Jul 23, 2025OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 16, 2026. FDAgent holds no copy that FDA posted.
- Mar 17, 2026FDA-FOIA-2026-2665Form 483· 1 of 4 sitesRecords released
- Oct 27, 2025FDA-FOIA-2025-12321Form 483No records found
Inspection ending Feb 27, 2024OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- May 27, 2025FDA-FOIA-2025-4707Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 15 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment4 of 4
- 21 CFR 211.100Written procedures; deviations4 of 4
- 21 CFR 211.22Responsibilities of quality control unit3 of 4
- 21 CFR 211.80General requirements3 of 4
- 21 CFR 211.166Stability testing3 of 4
- 21 CFR 211.67Equipment cleaning and maintenance2 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 4
Show all 15
- 21 CFR 211.160General requirements2 of 4
- 21 CFR 211.180General requirements2 of 4
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.130Packaging and labeling operations1 of 4
- 21 CFR 211.165Testing and release for distribution1 of 4
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations III · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Accupack MidwestD-U-N-S 139637433
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000122754 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000122754. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.