Actavis Laboratories UT, Inc.
577 S Chipeta Way, Salt Lake City, Utah, United States
FEI 1000117147DUNS 079589880
FDA has 12 inspections on file for Actavis Laboratories UT, Inc. in Salt Lake City, Utah (FEI 1000117147), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the seven FOIA requests for this site have asked FDA for this inspection's 483.
The most recent OAI inspection ended on Mar 19, 2024. No warning letter, court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.192, 21 CFR 211.113(a) and 21 CFR 211.56(a).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Actavis Laboratories UT, Inc. (D-U-N-S 079589880).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 12, 2009–2025
- 1 OAI · 7 VAI · 4 NAI
- Inspections with 483 observations shown
- 6 of 12
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 7 requests, latest Oct 26, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
12 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not written.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written and followed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules and instructions for protection of clean equipment from contamination prior to use.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Labels and labeling stored separately
Labels and other labeling materials are not stored separately with suitable identification for each different drug product, strength, dosage form or quantity of contents.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Contamination, chemical or physical change, deterioration
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy.
Accurate reproduction
The batch production and control records are deficient in that they are not checked for accuracy, dated, and signed.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on Oct 26, 2026.
Inspection ending Sep 19, 2025VAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jan 6, 2026. FDAgent holds no copy that FDA posted.
- Oct 26, 2026FDA-FOIA-2026-10380Form 483Records released
- Dec 4, 2025FDA-FOIA-2025-13602Form 483· 1 of 5 sitesRecords released
Inspection ending Mar 19, 2024OAI
3 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Dec 18, 2024FDA-FOIA-2024-11121Form 483Closed
- Jul 1, 2024FDA-FOIA-2024-5707Form 483Closed
- Jun 6, 2024FDA-FOIA-2024-4969Form 483· 1 of 4 sitesClosed
Inspection ending Aug 20, 2021VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 1, 2024FDA-FOIA-2024-5741Inspection recordsClosed
- Apr 1, 2022FDA-FOIA-2022-2406Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 12 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review4 of 6
- 21 CFR 211.56Sanitation2 of 6
- 21 CFR 211.100Written procedures; deviations2 of 6
- 21 CFR 211.113Control of microbiological contamination2 of 6
- 21 CFR 211.22Responsibilities of quality control unit1 of 6
- 21 CFR 211.42Design and construction features1 of 6
- 21 CFR 211.63Equipment design, size, and location1 of 6
- 21 CFR 211.67Equipment cleaning and maintenance1 of 6
Show all 13
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 6
- 21 CFR 211.122Materials examination and usage criteria1 of 6
- 21 CFR 211.188Batch production and control records1 of 6
- 21 CFR 211.194Laboratory records1 of 6
- 21 CFR 314.81Other postmarketing reports1 of 6
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Actavis Laboratories UT, Inc.D-U-N-S 079589880
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000117147 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000117147. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.