21 CFR 606.110: Plateletpheresis, leukapheresis, and plasmapheresis

FDA's inspection data lists 4 Form 483 citations of 21 CFR 606.110 at 3 facilities, from March 2012 to March 14, 2018.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
4
At 3 inspections
Facilities cited
3
Distinct FEIs
Most recent citation
Mar 14, 2018
A Plus Phlebotomy Services
Warning letters
0
State a violation of it

The regulation

The current text of 21 CFR 606.110 from the Electronic Code of Federal Regulations.

§ 606.110 Plateletpheresis, leukapheresis, and plasmapheresis.

(a) The use of plateletpheresis and leukapheresis procedures to obtain a product for a specific recipient may be at variance with the additional standards for specific products prescribed in this part provided that: (1) A physician has determined that the recipient must be transfused with the leukocytes or platelets from a specific donor, and (2) the procedure is performed under the supervision of a responsible physician who is aware of the health status of the donor, and the physician has determined and documented that the donor's health permits plateletpheresis or leukapheresis.

(b) Plasmapheresis of donors who do not meet the donor requirements of §§ 630.10, 630.15, 640.64 and 640.65 of this chapter for the collection of plasma containing rare antibodies shall be permitted only with the prior approval of the Director, Center for Biologics Evaluation and Research.

21 CFR Part 606: Current Good Manufacturing Practice for Blood and Blood Components, Subpart FRead on eCFR

Citations by year

Form 483 citations of 21 CFR 606.110 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 2 in 2012

Form 483 citations of 21 CFR 606.110 by inspection year
YearForm 483 citations
20122
20161
20181

How FDA words this citation

FDA's short descriptions and citation text on these 4 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Center approval for collection of rare antibodies2 citations
  • Supervision of qualified physician1 citations
  • Written certification1 citations

Citation text

  • “Performance of plateletpheresis not under the supervision of a qualified licensed physician who was aware of the health status of the donor.”1 citations
  • “Performance of plateletpheresis without a qualified licensed physician certifying in writing that the donor's health permitted plateletpheresis.”1 citations
  • “The plasmapheresis of donor(s) whose blood contained rare antibodies but did not meet the donor requirements for donor eligibility was performed without the prior approval of the Director, Center for Biologics Evaluation and Research.”1 citations
  • “The plasmapheresis of donor(s) whose blood contained rare antibodies but did not meet the donor requirements for donor eligibility, collection and plasmapheresis was performed without the prior approval of the Director, Center for Biologics Evaluation and Research.”1 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 606.110, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Often cited at the same inspection

Of the 3 inspections where FDA cited 21 CFR 606.110, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 606.110

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 606.110; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.