Medical Home Health Options dba The Plasma Source
Logan Square, 6550 Lower York Road, New Hope, Pennsylvania, United States
FEI 3009456363
FDA has one inspection on file for Medical Home Health Options dba The Plasma Source in New Hope, Pennsylvania (FEI 3009456363). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 19 citations from this inspection. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2016
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products19 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Transmissible blood disease
Each donor was not in good health on the day of donation, as indicated in part by a history and examination indicative of disease transmissible by blood transfusion (other than malaria).
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the processing and distribution of each unit of blood and blood components so that all steps can be clearly traced.
Donor reaction
Failure of the donor record to contain a full explanation of a donor reaction, while on the plasmapheresis premises or reported to the center after the donor has left the premises, including the measures taken to assist the donor and the outcome of the incident.
Equipment calibration frequency
Equipment used in the collection of blood and blood components is not observed, standardized and calibrated with at least the frequency required.
Name, address, unique facility identifier
The container label fails to include the address and unique facility identifier.
Show 14 more citations
Serological test
Failure to draw from each donor on the day of the first medical exam or plasmapheresis a sample of blood tested for total plasma or serum protein determination and serum protein electrophoresis or equivalent test.
Expiration date
The container label fails to include the expiration date, including the day, month, and year.
Donor consent
Failure to maintain the original or a clear copy or other durable record of the donor's written consent for participation in the plasmapheresis program or for immunization.
Proper name of product
The container label fails to include the proper name of the product in a prominent position.
Blood hemoglobin
Each donor was not in good health on the day of donation, as indicated in part by a blood hemoglobin level of less than 12.5 grams per 100 milliliters of blood or 38% hematocrit.
Determining donor suitability
Failure to have donor suitability determined by a qualified licensed physician or trained persons under his supervision.
Serum protein
Each donor was not in good health on the day of donation, as indicated in part by a total serum and plasma protein of less than 6.0 grams per 100 milliliters of blood.
Test for HIV, HBV, HCV
Failure to test each donation of blood and blood components intended for transfusion or for use in manufacturing a product for evidence of infection with HIV, HBV and HCV.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection, processing, storage and distribution of blood and blood components for further manufacturing purposes were not always maintained.
Center approval for collection of rare antibodies
The plasmapheresis of donor(s) whose blood contained rare antibodies but did not meet the donor requirements for donor eligibility, collection and plasmapheresis was performed without the prior approval of the Director, Center for Biologics Evaluation and Research.
Shipment/use of reactive units, units from deferred donors
Human blood or blood components that were reactive by a screening test for evidence of relevant transfusion-transmitted infection were shipped without meeting the exceptions set forth in the regulations.
Determination of lot numbers and supplies
Appropriate records are not available to determine the lot numbers of supplies used for specific units of the final product.
Qualifications of responsible personnel
The personnel responsible for the collection of blood or blood components are not adequate in training and experience, including professional training as necessary to assure competent performance of their assigned functions, and to ensure that the final product has the safety, purity, potency, identity and effectiveness it purports or is represented to possess.
Maintain and clean equipment
Failure to maintain equipment used in the collection of blood and blood products in a clean and orderly manner.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 606.20Personnel1 of 1
- 21 CFR 606.60Equipment1 of 1
- 21 CFR 606.100Standard operating procedures1 of 1
- 21 CFR 606.121Container label1 of 1
- 21 CFR 606.160Records1 of 1
- 21 CFR 610.40Test requirements1 of 1
- 21 CFR 640.631 of 1
- 21 CFR 640.65Plasmapheresis1 of 1
Show all 10
- 21 CFR 640.72Records1 of 1
- 21 CFR 606.110Plateletpheresis, leukapheresis, and plasmapheresis1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3009456363 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3009456363. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.