Skip to content

Medical Home Health Options dba The Plasma Source

Logan Square, 6550 Lower York Road, New Hope, Pennsylvania, United States

FEI 3009456363

FDA has one inspection on file for Medical Home Health Options dba The Plasma Source in New Hope, Pennsylvania (FEI 3009456363). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 19 citations from this inspection. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2016
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products19 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Transmissible blood disease

      Each donor was not in good health on the day of donation, as indicated in part by a history and examination indicative of disease transmissible by blood transfusion (other than malaria).

    2. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the processing and distribution of each unit of blood and blood components so that all steps can be clearly traced.

    3. Donor reaction

      Failure of the donor record to contain a full explanation of a donor reaction, while on the plasmapheresis premises or reported to the center after the donor has left the premises, including the measures taken to assist the donor and the outcome of the incident.

    4. Equipment calibration frequency

      Equipment used in the collection of blood and blood components is not observed, standardized and calibrated with at least the frequency required.

    5. Name, address, unique facility identifier

      The container label fails to include the address and unique facility identifier.

    Show 14 more citations
    1. Serological test

      Failure to draw from each donor on the day of the first medical exam or plasmapheresis a sample of blood tested for total plasma or serum protein determination and serum protein electrophoresis or equivalent test.

    2. Expiration date

      The container label fails to include the expiration date, including the day, month, and year.

    3. Donor consent

      Failure to maintain the original or a clear copy or other durable record of the donor's written consent for participation in the plasmapheresis program or for immunization.

    4. Proper name of product

      The container label fails to include the proper name of the product in a prominent position.

    5. Blood hemoglobin

      Each donor was not in good health on the day of donation, as indicated in part by a blood hemoglobin level of less than 12.5 grams per 100 milliliters of blood or 38% hematocrit.

    6. Determining donor suitability

      Failure to have donor suitability determined by a qualified licensed physician or trained persons under his supervision.

    7. Serum protein

      Each donor was not in good health on the day of donation, as indicated in part by a total serum and plasma protein of less than 6.0 grams per 100 milliliters of blood.

    8. Test for HIV, HBV, HCV

      Failure to test each donation of blood and blood components intended for transfusion or for use in manufacturing a product for evidence of infection with HIV, HBV and HCV.

    9. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection, processing, storage and distribution of blood and blood components for further manufacturing purposes were not always maintained.

    10. Center approval for collection of rare antibodies

      The plasmapheresis of donor(s) whose blood contained rare antibodies but did not meet the donor requirements for donor eligibility, collection and plasmapheresis was performed without the prior approval of the Director, Center for Biologics Evaluation and Research.

    11. Shipment/use of reactive units, units from deferred donors

      Human blood or blood components that were reactive by a screening test for evidence of relevant transfusion-transmitted infection were shipped without meeting the exceptions set forth in the regulations.

    12. Determination of lot numbers and supplies

      Appropriate records are not available to determine the lot numbers of supplies used for specific units of the final product.

    13. Qualifications of responsible personnel

      The personnel responsible for the collection of blood or blood components are not adequate in training and experience, including professional training as necessary to assure competent performance of their assigned functions, and to ensure that the final product has the safety, purity, potency, identity and effectiveness it purports or is represented to possess.

    14. Maintain and clean equipment

      Failure to maintain equipment used in the collection of blood and blood products in a clean and orderly manner.

Regulations FDA cited here

The 10 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 10

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009456363 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009456363. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.