Imperial Palace Commodity -Dongguan- Co., Ltd. warning letter, January 27, 2025
FDA's Center for Drug Evaluation and Research (CDER) issued this warning letter to Imperial Palace Commodity -Dongguan- Co., Ltd. of Dongguan Shi, Guangdong Sheng on January 27, 2025 and posted it on February 4, 2025. It states 4 violations, citing 21 CFR 211.84(d)(1), 211.84(d)(2), 211.100(a), 211.160(b) and 211.22(a).
Source: FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Read the full letter on fda.gov. FDAgent is independent of FDA.
- Issued
- Jan 27, 2025
- By CDER
- Posted by FDA
- Feb 4, 2025
- 8 days after issue
- Subject
- CGMP/Finished Pharmaceuticals/Adulterated
- As FDA lists it
- FDA reference
- MARCS-CMS 692842
- FDA's case number
Violations FDA states in this letter
Each numbered violation sentence that cites 21 CFR, quoted exactly from the letter. The full letter below explains each one.
- 1
“Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals (21 CFR 211.84(d)(1) and 211.84(d)(2)).”
21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1,818 Form 483 citations · 223 warning letters - 2
“Your firm failed to establish adequate written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess (21 CFR 211.100(a)).”
21 CFR 211.100Written procedures; deviations2,673 Form 483 citations · 175 warning letters - 3
“Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).”
21 CFR 211.160General requirements3,046 Form 483 citations · 88 warning letters - 4
“Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).”
21 CFR 211.22Responsibilities of quality control unit3,495 Form 483 citations · 275 warning letters
The facility
FDA's compliance action record for this letter (case 692842) names one facility. Each facility's FDA record on FDAgent has its full inspection history.
The letter
FDA's text of the letter as posted on fda.gov. FDAgent leaves out the address block, the greeting and the copy list, which name the people it was sent to.
Your facility is registered with the United States Food and Drug Administration (FDA) as a manufacturer of over-the-counter (OTC) drug products. FDA has reviewed the records you submitted in response to our March 4, 2024 request, and subsequent requests, for records and other information pursuant to section 704(a)(4) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) for your facility, Imperial Palace Commodity (Dongguan) Co., Ltd., FEI 3014838570, at No. 523 1st Liudong Road, Changlong Village, Huangjiang Town, Dongguang, Guangdong 523750, China.
This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations, parts 210 and 211 (21 CFR, parts 210 and 211).
Because your methods, facilities, or controls for manufacturing, processing, packing, or holding of drugs as described in your responses to our 704(a)(4) request do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the FD&C Act (21 U.S.C. 351(a)(2)(B)).
704(a)(4) Request for Records and Related CGMP Violations
Following review of records and other information provided pursuant to section 704(a)(4) of the FD&C Act, significant violations were observed including, but not limited to, the following:
1. Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals (21 CFR 211.84(d)(1) and 211.84(d)(2)).
Your firm manufactures OTC drug products such as alcohol wipes. Based on the records and information you provided, you did not demonstrate that you have adequately tested incoming components used in the manufacture of your drug products. For example, you failed to conduct adequate identity testing on your incoming components. Additionally, your firm relied on the certificates of analysis (COAs) from your suppliers and failed to establish the reliability of each of your suppliers’ COA for component specifications and characteristics at appropriate intervals.
Information provided indicates that you failed to demonstrate that you adequately test each shipment of each lot of glycerin for identity, a component at higher risk for diethylene glycol (DEG) and ethylene glycol (EG) contamination. We note that glycerin is an ingredient used in your alcohol wipe drug products. Identity testing of glycerin, along with other high-risk drug components1, includes a limit test in the United States Pharmacopeia (USP) to ensure that the component meets the relevant safety limits for levels of DEG or EG. Because you did not perform identity testing on each shipment of each glycerin lot using the USP identification tests that detects these hazardous impurities, you failed to assure the acceptability of this component for use in the manufacture of your drug products.
The use of ingredients contaminated with DEG or EG has resulted in various lethal poisoning incidents in humans worldwide. See FDA’s guidance document Testing of Glycerin, Propylene Glycol, Maltitol Solution, Hydrogenated Starch Hydrolysate, Sorbitol Solution, and Other High-Risk Drug Components for Diethylene Glycol and Ethylene Glycol to help you meet the CGMP requirements when manufacturing drugs containing ingredients at high-risk for DEG or EG contamination at https://www.fda.gov/media/167974/download.
You also failed to adequately test your incoming component, ethanol, used as an active ingredient in your alcohol wipes, for methanol. The use of ethanol contaminated with methanol has resulted in various lethal poisoning incidents in humans worldwide. See FDA’s guidance document Policy for Testing of Alcohol (Ethanol) and Isopropyl Alcohol for Methanol to help you meet the CGMP requirements when manufacturing drugs containing ethanol at https://www.fda.gov/media/173005/download.
Without adequate testing, you do not have scientific evidence that your incoming components conform to appropriate specifications before use in the manufacture of your drug products.
2. Your firm failed to establish adequate written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess (21 CFR 211.100(a)).
Process Validation
Based on the records and information you provided, you did not demonstrate that you have adequately validated the manufacturing process for your alcohol wipe drug products. For example, the records you provided to demonstrate your process validation for your drug products, included only reports of analytical test results.
Process validation evaluates the soundness of design and state of control of a process throughout its lifecycle. Each significant stage of a manufacturing process must be designed appropriately and assure the quality of raw material inputs, in-process materials, and finished drugs. Process qualification studies include intensive monitoring and testing throughout each significant process stage to characterize intra-batch variation and evaluate batches to determine whether an initial state of control has been established. Successful process qualification studies are necessary before commercial distribution. Thereafter, ongoing vigilant oversight of process performance and product quality is necessary to ensure you maintain a stable manufacturing operation throughout the product lifecycle.
See FDA’s guidance document Process Validation: General Principles and Practices for general principles and approaches that FDA considers appropriate elements of process validation, at https://www.fda.gov/media/71021/download.
Water System Validation
Your firm uses water as a component in your drug products. You have not demonstrated that your firm’s water system has been adequately designed and validated for its intended use. For example, your response states that your water system is qualified only for (b)(4) water. In addition, your (b)(4) water validation report did not include testing results for total organic carbon. Your firm has not demonstrated that the water is suitable for use and meets the USP (b)(4) Water monograph specifications.
3. Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).
Based on the records and information you provided, you did not demonstrate that you used an appropriate test method for microbiological testing as part of your stability program. For example, the records you provided for your stability program identified your microbiological testing method as “Antibacterial efficacy test-refer to USP 40 51>.” You reported results for “total aerobic microbial count,” “coliform bacteria,” and “fungi,” as well as other specified microorganisms, but your results reflect that your methods are not consistent with USP <51> Antimicrobial Effectiveness Testing. The methodology described in USP <51> is intended to demonstrate the effectiveness of added microbial preservatives; however, your response states that your drug products do not contain preservatives.
Without appropriate test methods, you do not have scientific evidence to support whether your drug products meet their established microbiological specifications through their labeled expiry.
4. Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).
The records and information you provided demonstrated that your quality unit (QU) did not effectively exercise its responsibilities to oversee the quality of your drug manufacturing operations. For example, your QU did not adequately exercise its authority over the establishment of controls in your Materials System and Laboratory Control System.
Your QU is responsible for fully exercising its authority and responsibilities. FDA is concerned that your QU may not be conducting appropriate oversight regarding CGMP operations. See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71023/download.
CGMP Consultant Recommended
Based upon the nature of the violations we identified at your firm, you should engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements. The qualified consultant should also perform a comprehensive six-system audit of your entire operation for CGMP compliance and evaluate the completion and efficacy of your corrective actions and preventive actions.
The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.
FDA placed products offered for import into the United States from your firm on Import Alert 66-40 on January 23, 2025.
Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may inspect to verify that you have completed corrective actions to any violations.
Failure to address any violations may also result in the FDA continuing to refuse admission of articles manufactured at Imperial Palace Commodity Dongguan Co., Ltd., at No. 523 1st Liudong Road, Changlong Village, Huangjiang Town, Dongguan, Guangdong 523750, China, into the United States under section 801(a)(3) of the FD&C Act, 21 U.S.C. 381(a)(3). Articles under this authority that appear to be adulterated may be detained or refused admission.
This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.
Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3014838570 and ATTN: Joel Hustedt.
Francis Godwin Director Office of Manufacturing Quality Office of Compliance Center for Drug Evaluation and Research
_________________________
1 Components with higher risk of DEG or EG contamination compared to other drug components.
Ask FDAgent about this warning letter
FDAgent reads the letter, the facility's inspections and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The letter, its text, dates, issuing office and subject come from FDA's warning letter pages.
- FDAgent leaves out the letter's address block, greeting and copy list, which name the people it was sent to, and quotes each numbered violation sentence that cites 21 CFR.
- Facilities come from FDA's compliance action record for the letter's case number, or the one FEI the letter names; inspections and citations come from FDA's Data Dashboard.
- FDAgent is independent of FDA.