Skip to content

The Compounding Shop Form 483, March 2013

FDA issued this Form 483 to The Compounding Shop in St Petersburg, Florida (FEI 3004668624) at the end of a drug inspection that ended March 22, 2013. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 22, 2013
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,953 days after the inspection
Facility
FEI 3004668624
St Petersburg, Florida

FDA's 12 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  2. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

  3. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  4. Lack of written stability program

    There is no written testing program designed to assess the stability characteristics of drug products.

  5. Clothing appropriate for duties performed

    Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

  6. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  7. Cleaning / Sanitizing / Maintenance

    Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  8. Calibration/Inspection/Checking not done

    Routine calibration of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

  9. Air Supply

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

  10. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

  11. Written Procedures to Remove Pyrogens

    There are no written standards or specifications, methods of testing, methods of cleaning, and methods of sterilization to remove pyrogenic properties.

  12. Microbiological testing

    Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3004668624, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.