Skip to content

TEVA Animal Health Form 483, April 2009

FDA issued this Form 483 to TEVA Animal Health in Saint Joseph, Missouri (FEI 1000118231) at the end of a veterinary inspection that ended April 21, 2009. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 21, 2009
Veterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
5,384 days after the inspection
Facility
FEI 1000118231
Saint Joseph, Missouri

FDA's 17 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Failing drug products not rejected

    Drug products failing to meet established standards, specifications, and quality control criteria are not rejected.

  2. Procedures not in writing, fully followed

    The responsibilities and procedures applicable to the quality control unit are not fully followed.

  3. Control procedures to monitor and validate performance

    Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

  4. Tablet or capsule weight variation

    The in-process control procedures were deficient in that it did not include an examination of tablet and capsule weight variation.

  5. Reserve drug product sample quantity - all tests

    The reserve sample of drug product does not consist of at least twice the quantity necessary to perform all the required tests of drug product.

  6. Adequate lighting not provided

    Adequate lighting is not provided in all areas.

  7. Annual visual exams of drug products

    Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

  8. Procedure Deviations Recorded and Justified

    Deviations from written production and process control procedures are not recorded and justified.

  9. Test methods

    The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.

  10. Acceptance of drug products

    Determinations of conformance to appropriate written specifications for acceptance are not made for drug products.

  11. Deviations from laboratory control requirements

    Deviations from written specifications are not justified.

  12. Extent of discrepancy, failure investigations

    Investigations of an unexplained discrepancy did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

  13. Training--operations, GMPs, written procedures

    Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.

  14. Complaint Handling Procedure

    Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

  15. Cleaning / Sanitizing / Maintenance

    Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.

  16. Valid stability test methods

    The written stability program for drug products does not include specific test methods.

  17. Investigations of discrepancies, failures

    There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • InjunctionJul 31, 2009CVM · 101 days after this inspection ended

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.