Bayer Healthcare Animal Health Inc
3915 S 48th Ter, Saint Joseph, Missouri, United States
FEI 1000118231
FDA has 6 inspections on file for Bayer Healthcare Animal Health Inc in Saint Joseph, Missouri (FEI 1000118231), from 2009 to 2014. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jul 24, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
The most recent OAI inspection ended on Apr 21, 2009. FDA's compliance record also lists one other action under this FEI: Injunction, . No warning letter or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2009–2014
- 1 OAI · 2 VAI · 3 NAI
- Inspections with 483 observations shown
- 3 of 6
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that closures conform to appropriate standards of identity, strength, quality and purity.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release.
Reactive/Additive/Absorptive Containers/Closures
Drug product containers or closures are reactive, additive, and absorptive so as to alter the safety, identity, strength, quality, and purity of the drug beyond the official or established requirements.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training and experience required to perform their assigned functions.
Show 3 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- NAINo objectionable conditions that need follow-upVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesNone
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices17 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Failing drug products not rejected
Drug products failing to meet established standards, specifications, and quality control criteria are not rejected.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Tablet or capsule weight variation
The in-process control procedures were deficient in that it did not include an examination of tablet and capsule weight variation.
Reserve drug product sample quantity - all tests
The reserve sample of drug product does not consist of at least twice the quantity necessary to perform all the required tests of drug product.
Show 12 more citations
Adequate lighting not provided
Adequate lighting is not provided in all areas.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.
Acceptance of drug products
Determinations of conformance to appropriate written specifications for acceptance are not made for drug products.
Deviations from laboratory control requirements
Deviations from written specifications are not justified.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.
Valid stability test methods
The written stability program for drug products does not include specific test methods.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 3
- 21 CFR 211.25Personnel qualifications2 of 3
- 21 CFR 211.100Written procedures; deviations2 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 3
- 21 CFR 211.160General requirements2 of 3
- 21 CFR 211.165Testing and release for distribution2 of 3
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.44Lighting1 of 3
Show all 14
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.94Drug product containers and closures1 of 3
- 21 CFR 211.166Stability testing1 of 3
- 21 CFR 211.170Reserve samples1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.198Complaint files1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- InjunctionCVM · VeterinaryFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000118231 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000118231. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.