Shertech Pharmacy Form 483, July 2019
FDA issued this Form 483 to Shertech Pharmacy in Easley, South Carolina (FEI 3002614375) at the end of a drug inspection that ended July 2, 2019. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Sep 16, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 2, 2019
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Sep 16, 2019
- 76 days after the inspection
FDA's 11 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
- FDCA 501(a)(2)(A)
Air flow quality, higher classified area
Your facility design allowed the influx of poor quality air into a higher classified area.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
- FDCA 501(a)(2)(A)
No sporicidal agents, cleanroom and ISO 5 area
Sporicidal agents were not used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Records not made readily available to FDA
Records associated with drug product components, containers, closures, labeling, production, control and distribution and within the retention period for such records, were not made readily available for authorized inspection.
- FDCA 501(a)(2)(A)
Personnel in aseptic processing, non-sterile gloves
Personnel engaged in aseptic processing were observed wearing non-sterile gloves.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.