Skip to content

Shertech Pharmacy

221 Cooper Ln Ste A, Easley, South Carolina, United States

FEI 3002614375

FDA has one inspection on file for Shertech Pharmacy in Easley, South Carolina (FEI 3002614375). It ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 11 citations from this inspection. They are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2019
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Sep 18, 2019
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Air flow quality, higher classified area

      Your facility design allowed the influx of poor quality air into a higher classified area.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Testing Each Component for Conformity with Specs

      Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

    4. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    5. FDCA 501(a)(2)(A)

      No sporicidal agents, cleanroom and ISO 5 area

      Sporicidal agents were not used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area.

    Show 6 more citations
    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    3. Records not made readily available to FDA

      Records associated with drug product components, containers, closures, labeling, production, control and distribution and within the retention period for such records, were not made readily available for authorized inspection.

    4. FDCA 501(a)(2)(A)

      Personnel in aseptic processing, non-sterile gloves

      Personnel engaged in aseptic processing were observed wearing non-sterile gloves.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    6. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Sep 18, 2019. It asked for a Form 483.

  • Inspection ending Jul 2, 2019OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Sep 18, 2019FDA-FOIA-2019-8718Form 483Open

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002614375 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002614375. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.