Pharmakon Compounding Pharmacy Inc. Form 483, May 2016

FDA issued this Form 483 to Pharmakon Compounding Pharmacy Inc. in Noblesville, Indiana (FEI 3012248018) at the end of a drug inspection that ended May 6, 2016. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
May 6, 2016
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
2,812 days after the inspection
Facility
FEI 3012248018
Noblesville, Indiana

FDA's 11 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  2. Clothing appropriate for duties performed

    Clothing of personnel engaged in the manufacturing , processing and packing of drug products is not appropriate for the duties they perform.

  3. Calibration/Inspection/Checking not done

    Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

  4. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  5. Equipment to control conditions

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

  6. Sterility/pyrogen-free testing

    Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

  7. Lack of written stability program

    There is no written testing program designed to assess the stability characteristics of drug products.

  8. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  9. Penicillin processing area not kept separate

    The operations relating to the processing of penicillin are not performed in facilities separate from those used for other drug products for human use.

  10. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

  11. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterSep 7, 2017CDER · 489 days after this inspection ended

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.