Skip to content

Martin Avenue Pharmacy, Inc. Form 483, July 2014

FDA issued this Form 483 to Martin Avenue Pharmacy, Inc. in Naperville, Illinois (FEI 3003381432) at the end of a drug inspection that ended July 21, 2014. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 21, 2014
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,467 days after the inspection
Facility
FEI 3003381432
Naperville, Illinois

FDA's 15 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Defined areas of adequate size for operations

    The control systems necessary to prevent contamination or mix-ups are deficient.

  2. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  3. Handling and Storage to Prevent Contamination

    There was a failure to handle and store drug product containers at all times in a manner to prevent contamination.

  4. Prepared for each batch, include complete information

    Batch production and control records do not include complete information relating to the production and control of each batch.

  5. FDCA 501(a)

    Drug Field Exam

    During a field examination of drug products at your facility the following was observed:

  6. Containers & Closures Clean, Sterilized, Pyrogen-free

    Drug product containers and closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.

  7. Sterility/pyrogen-free testing

    Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

  8. Reports of Analysis (Components)

    Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

  9. Lack of written stability program

    There is no written testing program designed to assess the stability characteristics of drug products.

  10. Equipment construction - reactive surfaces

    Equipment surfaces that contact components and in-process materials are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.

  11. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

  12. Establishment of time limitations

    Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

  13. Cleaning / Sanitizing / Maintenance

    Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  14. Protection from external factors

    Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.

  15. Equipment for Environmental Control

    Equipment for adequate control over micro-organisms is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterMar 18, 2015CDER · 240 days after this inspection ended

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.