Baxter Healthcare Corporation Form 483, April 2026

FDA issued this Form 483 to Baxter Healthcare Corporation in Round Lake, Illinois (FEI 1416980) at the end of a drug inspection that ended April 2, 2026. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on September 29, 2026.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 16, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 2, 2026
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Nov 16, 2026
228 days after the inspection
Facility
FEI 1416980
Round Lake, Illinois

FDA's 9 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Defined areas of adequate size for operations

    The control systems necessary to prevent contamination or mix-ups are deficient.

  2. Written procedures not established/followed

    Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

  3. Equipment Design, Size and Location

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

  4. Training--operations, GMPs, written procedures

    Employees are not given training in the particular operations they perform as part of their function.

  5. Procedure Deviations Recorded and Justified

    Deviations from written production and process control procedures are not recorded.

  6. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  7. Following/documenting laboratory controls

    Established specifications, standards, sampling plans, test procedures and laboratory control mechanisms are not followed and documented at the time of performance.

  8. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.

  9. Acceptance/Rejection Levels

    The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 1416980, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.