American Specialty Pharmacy Form 483, August 2018
FDA issued this Form 483 to American Specialty Pharmacy in San Antonio, Texas (FEI 3012174424) at the end of a drug inspection that ended August 23, 2018. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on April 5, 2021.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 14, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Aug 23, 2018
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Nov 14, 2019
- 448 days after the inspection
FDA's 6 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing, instructions, procedures, specifications, special notations and precautions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Statement of methods and data
Laboratory records do not include a statement of each method used in the testing of a sample and the location of data that establish that the methods used in the testing of the sample meet proper standards of accuracy and reliability as applied to the product tested.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterApr 5, 2021American Specialty Pharmacy, Inc. dba ASP Cares warning letter, April 5, 2021CDER · 956 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3012174424, newest first.
- Form 483, August 2018Inspection ended Aug 23, 2018 · Posted Apr 30, 2019OAI
- Form 483, March 2017Inspection ended Mar 2, 2017 · Posted Jan 17, 2024VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.