RNA Bio/Pharma Inc
19470 Navarre Coulee Rd, Chelan, Washington, United States
FEI 3023116DUNS 883081523
FDA has 4 inspections on file for RNA Bio/Pharma Inc in Chelan, Washington (FEI 3023116), from 2008 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three FOIA requests have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.166(c)(1) and 21 CFR 211.84(d)(2).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is RNA BIO/PHARMA INC. (D-U-N-S 883081523).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2008–2025
- 1 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 4
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest May 15, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lack of quality control unit
There is no quality control unit.
Component identification test
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Homeopathic drugs, assessment of stability
There is no written assessment of stability of homeopathic drug products based at least on testing or examination of the drug product for compatibility of the ingredients and marketing experience with the drug product to indicate that there is no degradation of the product for the normal or expected period of use.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Homeopathic drugs, assessment of stability
There is no written assessment of stability of homeopathic drug products based at least on testing or examination of the drug product for compatibility of the ingredients and marketing experience with the drug product to indicate that there is no degradation of the product for the normal or expected period of use.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complaint Investigation/Follow-Up Findings
Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Retest of approved components/containers/closures
Approved components are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.
Homeopathic drugs, assessment of stability
There is no written assessment of stability of homeopathic drug products based at least on testing or examination of the drug product for compatibility of the ingredients and marketing experience with the drug product to indicate that there is no degradation of the product for the normal or expected period of use.
Cleaning/maintenance records not kept
Records are not kept for the maintenance, cleaning, and inspection of equipment.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on May 15, 2026. Each one asked for a Form 483.
Inspection ending Apr 11, 2025OAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Aug 26, 2025. FDAgent holds no copy that FDA posted.
- May 15, 2026FDA-FOIA-2026-4988Form 483· 1 of 5 sitesWithdrawn
- Aug 28, 2025FDA-FOIA-2025-10264Form 483Records released
- Jul 15, 2025FDA-FOIA-2025-8711Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 9 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.166Stability testing3 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.87Retesting of approved components, drug product containers, and closures1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
Show all 9
- 21 CFR 211.198Complaint files1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- RNA BIO/PHARMA INC.D-U-N-S 883081523
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3023116 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3023116. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.