Sani-Care Salon Products, Inc
51 Curtis Ct Sw Ste B, Cartersville, Georgia, United States
FEI 3014759234
FDA has 2 inspections on file for Sani-Care Salon Products, Inc in Cartersville, Georgia (FEI 3014759234), from 2023 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the four FOIA requests for this site have asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations II). No court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.160(b) and 21 CFR 211.22(a).
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2023–2025
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 4 requests, latest Oct 8, 2026
- Warning letters
- · CDER · Division of Pharmaceutical Quality Operations II ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
Lack of quality control unit
There is no quality control unit.
Rejecting When Specifications Not Met
Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.
Distribution Record Requirements
Distribution records do not contain the date and quantity shipped and lot or control number of drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Show 4 more citations
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established.
Retention time of reserve samples, in general
You did not retain reserve samples for drug products for one year after the expiration dates of the drug products.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing and holding.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Retest of approved components/containers/closures
Approved components, drug product containers and closures are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.
Show 3 more citations
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Lack of quality control unit
There is no quality control unit.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Oct 8, 2026. Each one asked for a Form 483.
Inspection ending Jan 17, 2025OAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 30, 2026. FDAgent holds no copy that FDA posted.
- Oct 8, 2026FDA-FOIA-2026-9825Form 483· 1 of 2 sitesRecords released
- May 19, 2026FDA-FOIA-2026-5097Form 483· 1 of 5 sitesClosed
- May 12, 2025FDA-FOIA-2025-4208Form 483· 1 of 5 sitesClosed
Inspection ending Nov 3, 2023OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 2, 2024FDA-FOIA-2024-8571Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.87Retesting of approved components, drug product containers, and closures1 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 2
- 21 CFR 211.137Expiration dating1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
Show all 13
- 21 CFR 211.170Reserve samples1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.196Distribution records1 of 2
- 21 CFR 211.198Complaint files1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations II · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014759234 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014759234. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.