Sanit Technologies, LLC dba Durisan
7810 25th Ct E Unit 106, Sarasota, Florida, United States
FEI 3014538924
FDA has 2 inspections on file for Sanit Technologies, LLC dba Durisan in Sarasota, Florida (FEI 3014538924), from 2019 to 2021. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER · Office of Pharmaceutical Quality Operations, Division II).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.160(b) and 21 CFR 211.166(a).
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2019–2021
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing and holding.
Training , Education , Experience overall
Employees engaged in the processing, packing and holding of a drug product lack the training required to perform their assigned functions.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Show 4 more citations
Cleaning/maintenance records not kept
Records are not kept for the maintenance, cleaning, sanitizing and inspection of equipment.
Sampling and testing plans not followed
Written procedures for sampling and testing plans are not followed for each drug product.
Lack of quality control unit
There is no quality control unit.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Regulations FDA cited here
The 9 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.166Stability testing2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
Show all 9
- 21 CFR 211.192Production record review1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Office of Pharmaceutical Quality Operations, Division II · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014538924 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014538924. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.