Skip to content

Premier Trends LLC

4 Elisa Dr, Monroe Twp, New Jersey, United States

FEI 3014373428

FDA has 2 inspections on file for Premier Trends LLC in Monroe Twp, New Jersey (FEI 3014373428), from 2019 to 2021. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations I).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2019–2021
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest Jul 30, 2024
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Calibration/Inspection/Checking not done

      Routine calibration and checking of electronic equipment is not performed according to a written program designed to assure proper performance.

    2. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    4. Batch production and Batch Control Record Requirements

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing and holding.

    5. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval and rejection of components, drug product containers and closures.

    2. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Component written specification

      Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

    4. Calibration/Inspection/Checking not done

      Routine calibration, inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

    5. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    Show 4 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. GMP Training Frequency

      GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    3. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    4. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 30, 2024. Each one asked for a Form 483.

  • Inspection ending Sep 29, 2021OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 30, 2024FDA-FOIA-2024-6636Form 483Closed
  • Inspection ending Jun 28, 2019OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 30, 2024FDA-FOIA-2024-6635Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 10 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 10

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3014373428 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3014373428. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.