Ocubright Tear Stain Remover, Inc.
185 E 85th St #4N, New York, New York, United States
FEI 3013217028
FDA has 2 inspections on file for Ocubright Tear Stain Remover, Inc. in New York, New York (FEI 3013217028), from 2017 to 2018. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
FDA issued a warning letter on (CVM). No court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.165(a), 21 CFR 211.188 and 21 CFR 211.84(a).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2017–2018
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CVM ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the education and training required to perform their assigned functions.
Lack of quality control unit
There is no quality control unit.
Procedures are written, and followed
Procedures designed to assure that correct labels, labeling and packaging materials are used for drug products are not written and followed.
Show 7 more citations
Components withheld from use pending release
Each lot of components, drug product containers and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Records not made readily available to FDA
Records associated with drug product components, containers, closures, labeling, production, control and distribution and within the retention period for such records, were not made readily available for authorized inspection.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Retention time of reserve samples, in general
You did not retain reserve samples for drug products for one year after the expiration dates of the drug products.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established, written and followed.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
- OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
Components withheld from use pending release
Each lot of is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.165Testing and release for distribution2 of 2
- 21 CFR 211.188Batch production and control records2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.130Packaging and labeling operations1 of 2
- 21 CFR 211.137Expiration dating1 of 2
Show all 13
- 21 CFR 211.170Reserve samples1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.198Complaint files1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCVM · VeterinaryFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013217028 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013217028. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.