Stonegate Pharmacy LP
2501 W William Cannon Dr Ste 203, Austin, Texas, United States
FEI 3012038236
FDA has 3 inspections on file for Stonegate Pharmacy LP in Austin, Texas (FEI 3012038236), from 2016 to 2019. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 4 citations from this inspection. They are listed below.
The most recent OAI inspection ended on Mar 2, 2016. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2016–2019
- 1 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 3 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Disinfecting materials, aseptic processing area
Equipment was and Materials or supplies were not disinfected prior to entering the aseptic processing areas.
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had difficult to clean and particle-generating equipment or surface.
- FDCA 501(a)(2)(A)
Hazardous drugs, prevention of cross-contamination
You produced hazardous drugs without providing adequate containment and segregation to prevent cross-contamination.
- FDCA 501(a)(2)(A)
Improper gowning, contamination
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate media fill challenge
Media fills were not performed that closely simulate appropriate, worst-case activities and conditions. Media fill conducted by your aseptic technicians do not simulate worst-case scenarios or most challenging conditions. Inhalation Solution Lot # 04052018:86@39 consisting (b)(4). In addition, your firm has also produced a batch 03202018:94@2 consisting of !l>H•J vials each containing (2m1-100m1) and batch sizes can be in excess of (b) placing [(6) (-4) [(b) (4)]. This is a repeat observation from the previous inspection conducted in 2016. For example, your firm produced a batch of Glutathione 5% of (b)(4) each containing (b)(4) of product. In production of Chorionic Gonadotropin 10000IU/ml Solution, Lot # (b)(4) of product. Your firm routinely fills various size vials. Your firm's current media fill test procedure involves operations that do not represent routine production nor do they simulate worst-case activities that provide a challenge to aseptic operations.
- Observation 2
Improper handwashing and gowning
Personnel hand washing procedure was conducted in a way that may have caused the gowning apparel to become contaminated. On 6/5/2018, I observed the sterile technician remove her lab coat, cap and replace her shoe covers prior to entering the clean side of the ISO7 anteroom where she proceeded to wash her hands before sterile gowning. During the hand washing procedure, I observed tap water from the sink splashing on the floor next to her shoes which were covered with shoe covers. She proceeded to don sterile garments such as a sterile mask, sterile gown, sterile gloves but did not change her shoe covers. The shoe covers may have been contaminated with microbiological organisms found in tap water. She then entered the ISO7 buffer room containing the ISO5 laminar air flow hood.
Show observations 3 to 4
- Observation 3
Sterilization validation for pellets
Validation studies are not used properly to verify the adequacy of sterilization to sterilize vials of Testosterone in (b)(4). However, your firm does not follow the manufacturer (instructions) which state that (b)(4) is to be (b)(4). Your firm (b)(4) Testosterone/Anastrozole and/or Estradiol pellets in the (b)(4) (15)(4) are not processed or subjected to the same conditions (b)(4) parameters utilized to sterilize the pellets are adequate. Testosterone/Anastrozole and Estradiol pellets were dispensed since 3/1/2018. There is no assurance that the (b)(4) used to house the pellets were sterilized as the pellets therefore there is no assurance that the (b)(4) parameters are adequate. Approximately (b)(4) prescriptions of Testosterone (b)(4) have been distributed that were not processed under validated sterilization conditions.
- Observation 4
Non-sterile stock solutions used
Stock solutions used in the preparation of sterile finished drug products are not placed in sterile containers. Your firm prepares (b)(4) stock solution for production of Chorionic Gonadotropin Solution (HCG) in various strengths such as but not limited to 5,000 IU/ml and 10,000 IU/ml. The (b)(4) stock solution is not sterile and is not placed in sterile containers. The following lots (b)(4) have been prepared without being sterilized nor stored in sterile containers to limit or reduce bioburden to control potential proliferation of bacterial endotoxins. The beyond use date for this stock solution is (b)(4). Since 3/1/2018, approximately (b)(4) prescriptions have been produced using the stock solution that was not sterilized nor stored in sterile containers.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Containers & Closures Clean, Sterilized, Pyrogen-free
Drug product containers and closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Show 7 more citations
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Calibration/Inspection/Checking not done
Routine calibration of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Protection from external factors
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.28Personnel responsibilities1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.94Drug product containers and closures1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.166Stability testing1 of 2
Show all 10
- 21 CFR 211.167Special testing requirements1 of 2
- 21 CFR 211.192Production record review1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012038236 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012038236. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.