FDA has 3 inspections on file for Barclay, Luke, & Pillai Specialty Pharmacy, PLLC in Las Vegas, Nevada (FEI 3011888866), from 2016 to 2022. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published 5 citations from this inspection. They are listed below.

The most recent OAI inspection ended on Dec 14, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.165(a) and FDCA 501(a)(2)(A).

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2016–2022
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
4 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    2. FDCA 501(a)(2)(A)

      Cleanliness, ISO-classified areas

      The ISO 5 classified aseptic processing areas had difficult to clean and visibly dirty equipment or surface.

    3. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    4. FDCA 501(a)(2)(A)

      Non-microbial contamination, production area

      Non-microbial contamination was observed in your production area.

    5. FDCA 501(a)(2)(A)

      Ceiling tiles, cleanroom

      Unsealed, loose ceiling tiles were observed in your cleanroom.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. FDCA 501(a)(2)(A)

      Lack of HEPA filter, sterile product area

      You did not have a HEPA filter over the area to which sterile product was exposed.

    3. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the to produce aseptic conditions.

    4. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    5. Clothing appropriate for duties performed

      Clothing of personnel engaged in the of drug products is not appropriate for the duties they perform.

    Show 6 more citations
    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    2. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    4. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    5. Prepared for each batch, include complete information

      Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.

    6. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic techniques

      OBSERVATION 1 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. Specifically, Video recordings taken during sterile production as well as our observations during the inspection revealed inappropriate aseptic techniques used during production, including: A. We observed your firm's sterile production of Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution), Lot# 112716sb, which occurred on 11/27/2016. The sash of the (b)(4) Laminar Air Flow Hood (LAFH) was in an upright opened position the entire time. This can adversely affect the air intake. This can affect the air intake and HEPA unidirectional air flow of the critical ISO 5 zone. B. On 12/14/2016, we observed the sterile production of Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution) Lot# 121416jp. This is a (b)(4) product. We observed Pharmacist (b)(4) placing arms and hands directly over sterile open vials, during filling operations, blocking the path of HEPA unidirectional airflow of the ISO 5 zone. i. We observed a sterile lint free wipe placed over the front grille of the LAFH, obstructing the air intake of the ISO 5 LAFH. ii. We observed the pharmacist spray on gloves with sterile (b)(4), but did not allow the (b)(4) to dry before proceeding with further sterile drug production. C. D.

    2. Observation 2

      Inadequate cleanroom construction/maintenance

      OBSERVATION 2 Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations. Specifically, A. Your firm's cleanroom design is inadequate in that there are two rows of grilles from the ISO 7 cleanroom directly into the unclassified area of the facility. We observed the openings within each grille were approximately 1/16 to 1/2 inch wide. The openings can be adjusted to as wide as approximately 1 inch. The dimensions of each grille are approximately 12 x 47 inches. If there is a loss of positive pressure from the ISO 7 cleanroom, there could be potential backflow of air from the unclassified area into the ISO 7 clean. B. On 12/14/2016, we observed Pharmacist (b)(4) performing cleaning of the ISO 7 cleanroom and ISO 5 LAFH. We observed (b)(4) did not follow the minimum (b)(4) dwell time required for sporicidal activity of the disinfectant. For example, he cleaned the inside of the ISO 5 LAFH sash with the sporicidal disinfectant and wiped the disinfectant after approximately [illegible]. C. Your firm's (b)(4) certification of your ISO 5 LAFH is not performed under dynamic conditions representing actual use during production. For example, on 12/14/2016, (b)(4) aseptic operations in the ISO 5 LAFH while producing Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution). Furthermore, your firm does not maintain a video to document the air flow patterns observed during your (b)(4) certification. D. Your firm failed to perform environmental and personnel monitoring during the production of sterile drug products. Environmental monitoring performed on a (b)(4) was not performed under dynamic conditions simulating actual operations. For example, we observed (b)(4) producing Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution) on 12/14/2016, but (b)(4) of your ISO 5 LAFH does not indicate it was performed under dynamic conditions, including (b)(4). Environmental and personnel monitoring was not performed during the production of this batch. E. Your firm currently (b)(4) in the ISO 7 cleanroom, which according to Pharmacist (b)(4) was last used on 12/09/2016. The (b)(4), which (b)(4), can (b)(4) lint in the ISO 7 cleanroom, (b)(4) and during (b)(4). The (b)(4) is used for (b)(4) purposes and for equipment including (b)(4).

    Show observations 3 to 13
    1. Observation 3

      Inappropriate personnel gowning

      OBSERVATION 3 Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform. Specifically, Video recordings taken during sterile production as well as our observations during the inspection revealed inappropriate gowning was used during production, including: A. We observed your pharmacists on multiple occasions enter the cleanroom area with inadequate gowning. For example, on 11/09/2016, 11/30/2016, and 12/05/2016, pharmacists entered the ISO 7 cleanroom wearing only street clothes (i.e., no cleanroom garb at all). Also, on 11/10/2016, 11/27/2016, and 12/05/2016, we observed the pharmacists donning non-sterile gowns open in the back, non-sterile gloves, and non-sterile head cover while performing sterile drug production. B. On 11/27/2016 your firm produced Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution) Lot# 112716sb. We observed non-sterile head covers, non-sterile gowns with open backs, and non-sterile foot covers were donned, non-sterile gloves were worn by Pharmacist (b)(4). No sterile garb worn by the pharmacists were sterile masks. Also, eye goggles were not used. We observed the pharmacists' eyes, skin on the forehead, both cheeks, and entire neck areas were exposed. C. On 12/14/2016 your firm produced Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution) Lot# 121416jp. Sterile apparel was donned; however, gowning was performed in such a manner as to compromise the sterility of the apparel. For example, we observed the pharmacist use bare hands to handle and don sterile mask, sterile goggles, and sterile gowns. Additionally, we observed the sleeves and legs of the sterile gown were allowed to touch the dirty side of the anteroom floor. Also, when donning sterile gloves, we observed the pharmacist touched the sterile glove surfaces with bare hands.

    2. Observation 4

      Quality unit lacks authority

      OBSERVATION 4 The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred. Specifically, your firm has not established a quality control unit to verify production and control records are accurate and complete. Compounding records we reviewed revealed instances where Pharmacists are performing sterile production and also (b)(4). Also, on multiple occasions, your firm's pharmacists falsified records such as the Sterile Room Documentation Log for 2016. A. Your firm's pressure gauges have not been calibrated since your cleanroom was installed in (b)(4). In addition, there were no identifiers for the pressure gauges to determine which gauge is used to identify the pressure from each area of the facility. Furthermore on 12/12/2016, Pharmacist (b)(4) signed the log book indicating the pressure gauges were within the specified range. However, when questioned, he was unable to identify which pressure gauge corresponded to each area of facility. After your firm placed labels on the pressure gauges, we observed the pressure gauge for the (b)(4) read "0" in the morning and afternoon of 12/12/2016. The (b)(4) is required to maintain positive pressure at all times. B. Your firm documents the (b)(4) disinfection/cleaning of the cleanroom and anteroom in the Sterile Room Documentation Log for 2016. We observed that the log was completed on multiple days when cleaning was either not performed or not completed according to your firm's written procedures, as evidenced during our review of your video recordings including the following days: 1. On 11/27/2016, (b)(4) of Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution) were produced. 2. On 12/05/2016, (b)(4) of 0.2% Cyclosporine and (b)(4) of 0.1% Cyclosporine eye drops were produced.

    3. Observation 5

      Insufficient staff training

      OBSERVATION 5 Employees engaged in the manufacture and processing of a drug product lack the education, training and experience required to perform their assigned functions. Specifically, Your firm does not maintain a formal training program. Throughout the inspection and our review of your firm's video records, we observed multiple deficiencies regarding your firm's pharmacists' lack of training and experience as evidenced by inappropriate and inadequate gowning of pharmacists in the ISO 7 cleanroom, cleaning operations not being performed, inadequate aseptic technique of pharmacists in the ISO 5 LAFH; and failing to perform the (b)(4).

    4. Observation 6

      Sterility testing not performed

      OBSERVATION 6 Each batch of drug product purporting to be sterile and/or pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, A. Your firm has not demonstrated product suitability according to the compendial method for the sterility testing of Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution). Your firm has distributed this product to customers prior to demonstrating method suitability. B. Your firm does not perform sterility, endotoxin, and potency testing on each lot of sterile patient specific drug produced, for example, HCG pre-filled syringes, and Caffeine benzoate liter bags.

    5. Observation 7

      Incomplete product release testing

      OBSERVATION 7 Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. Specifically, A. Each batch of your firm's sterile drug product, Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution) is tested for potency by a contract testing laboratory. However, the potency testing method for Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution) has not been validated to assure method suitability. B. Your firm's sterile drug product Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution) contains a preservative, (b)(4). Your firm has not tested the preservative content in the batches at the time of release.

    6. Observation 8

      Inadequate laboratory controls/visual inspection

      OBSERVATION 8 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug product conform to appropriate standards of identity, strength, quality and purity. Specifically, A. Your firm does not have a written procedure that describes the visual inspection process for sterile injectable products produced by your facility. Your firm does not perform 100% visual inspection, against a contrasting background for product contamination prior to distribution, such as HCG pre filled syringes. B. Your firm failed to conduct any inspection to the extent possible for the presence of observable foreign and particulate matter for sterile ophthalmic preparations. For example on 12/14/2016, Pharmacist (b)(4) stated that the firm does not have a written procedure for visual inspection, but he uses (b)(4).

    7. Observation 9

      No stability testing program

      OBSERVATION 9 There is no written testing program designed to assess the stability characteristics of drug products. Specifically, We observed inconsistencies with the product storage conditions and Beyond Use Date used on the product label for Meta PT Eye Drops Solution (Phenylephrine HCl 2.5%, Tropicamide 1% Ophthalmic Liquid Solution). The firm used the following information on three lots of Meta PT Eye Drops: i. Lot# 112716sb; Manufactured 11/27/2016; Expiration Date 12/27/2016; Storage: Refrigerated ii. Lot# 121416jp; Manufactured 12/14/2016; Expiration Date 12/29/2016; Storage: Refrigerated iii. Lot# 121416sb; Manufactured 12/14/2016; Expiration Date 12/28/2016; Storage: Room Temperature Additionally, the samples that are on stability for this product are (b)(4) although the product distributed is labeled to be held under refrigerated conditions. Although there is analytical potency data from an external laboratory, the Certificate of Analysis (COA) states "The method(s) used for testing are not validated." Therefore, the firm does not have potency data to support the claimed shelflife/expiration dating of the finished product, listed above. Further, your firm stated that they are basing the expiration date on the proposed USP <797> refrigerated and room temperature BUD of 42 days. This proposed BUD is ongoing review and has not been finalized. The established <797> BUD is 3 days for refrigerated and 24 hours for room temperature.

    8. Observation 10

      Failure to investigate discrepancies

      OBSERVATION 10 There is a failure to thoroughly review any unexplained discrepancy, whether or not the batch has been already distributed. Specifically, A. On November 26, 2016, Pharmacist (b)(4) documented the temperature as 1°C, and indicated in the temperature log it was within the required specification of (b)(4). Also, there is no recording of temperature for November 24, 25, and 27, 2016. Your firm did not conduct an investigation for a temperature Out of Specification (OOS) for Bulk Drug Substances held in your cold storage refrigerator. B. Your firm did not perform investigations for incidences where pharmacists entered the ISO 7 cleanroom inappropriately gowned. C. Your firm did not conduct investigations for incidences where Pharmacist S.B. and Pharmacist (b)(4) performed inadequate aseptic technique.

    9. Observation 11

      Incomplete batch production records

      OBSERVATION 11 Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, Compounding records that we reviewed did not include the actual drug substance or excipient lot number used to produce the drug product, detailed production instructions, and lacked a specimen label of the finished drug product.

    10. Observation 12

      Inadequate label/packaging controls

      OBSERVATION 12 Examination of packaging and labeling materials for suitability and correctness before packaging operations is not performed and not documented in the batch production records. Specifically, Your firm does not have adequate controls for issuing labels, examining issued labels, and reconciliation of used labels. In addition, your firm does not have adequate controls to ensure proper identification of filled containers prior to labeling. For example, we observed Pharmacist (b)(4) issue new labeling for the following lots without review or approval: • Lot# 121416jp; Manufactured 12/14/2016; Expiration Date 12/29/2016; Storage: Refrigerated • Lot# 121416sb; Manufactured 12/14/2016; Expiration Date 12/28/2016; Storage: Room Temperature Also, your firm does not document an examination for accuracy of the label prior to release of the drug product.

    11. Observation 13

      Component certificates missing

      OBSERVATION 13 Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality. Specifically, The following bulk drug substances used by your facility to produce drug products are not each accompanied by a valid certificate of analysis: • Human Chorionic Gonadotropin (HCG), Lot# (b)(4) • Folic Acid Lot# (b)(4) • Levocetirizine Hydrochloride Lot# (b)(4) • Lot# (b)(4)

Regulations FDA cited here

The 10 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 10

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011888866 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011888866. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.