Skip to content

Empower Clinic Services LLC dba Empower Pharma

Texas

FEI 3011887629

FDA has 6 inspections on file for Empower Clinic Services LLC dba Empower Pharma in Texas (FEI 3011887629), from 2015 to 2025. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent has not read its observations yet; the PDF has them.

The most recent OAI inspection ended on Aug 28, 2024. FDA has issued 3 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.

Seven regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
6, 2015–2025
4 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
5 of 6
1 PDF not read yet · 2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
6 posted
Requested under FOIA
5 requests, latest Jul 9, 2026
Warning letters
· CDER ↗
3 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    4. FDCA 503B(a)(10)(B)

      Drug product container, fails to include

      The container of your outsourcing facility's drug products does not include information required by section 503B(a)(10)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).

    5. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    Show 3 more citations
    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 16 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    2. FDCA 503B(a)(10)

      Drug product label, outsourcer facility

      The labels of your outsourcing facility's drug products are deficient.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    4. Failure to submit ADE report

      Adverse drug experience information has not been reported to FDA.

    5. Containers & Closures Clean, Sterilized, Pyrogen-free

      Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.

    Show 11 more citations
    1. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, handling, sampling, testing, approval and rejection of components.

    2. Written in-process control procedures

      Written procedures are not established and followed that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    4. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    6. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    7. Review of representative number of batches

      Written procedures are not established and followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    8. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    9. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    10. FDCA 503B(b)(2)(A)

      Outsourcing facility, compounded drug report follow up

      Your outsourcing facility did not submit a report to FDA identifying the drugs compounded during the previous six month period.

    11. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Environmental monitoring deficiencies

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, your firm's procedure, T06.04 (b) requires that operators document differential pressure, relative humidity, and temperature before and during sterile drug production. Your procedure fails to require the recording and/or documentation of these results as part of your firm batch record. Humidity Monitoring Logs dated 2/4/2019 through 2/28/2020 demonstrated that your firm did not always document the differential pressure, relative humidity, and temperature in each ISO classified area. You failed to maintain adequate environmental controls during sterile drug production.

    2. Observation 2

      Missing validated hold-times

      Time limits are not established when appropriate for the completion of the quality of the drug product. Specifically, your firm failed to establish validated hold-times for sterilized bulk [illegible] to mitigate the risk of contamination of finished [illegible]. Your firm has not established a written hold-time procedure and did not fully write and follow it. Selected batch records did not document the date production process steps were performed. Drug Product Description Lot# Formulation Leuprolide 10mg/ml 64738 Glycine 50mg/ml 64619 Testosterone Cypionate GSO (5 ml) 200 mg/ml Injectable 64579 [illegible] 56796 Testosterone Cypionate GSO (5 ml) 50 mg/ml Injectable Pyridoxine HCL (Vit B6) (30 ml) 62303 100 mg/ml Injectable. Your firm's management reported the firm had [illegible].

    Show observations 3 to 6
    1. Observation 3

      Quality unit procedure and change control failures

      The responsibilities and procedures applicable to the quality control unit are not adequate. Specifically, your firm failed to adequately write [illegible] firm's quality unit: A. Your firm failed to adequately implement your firm's change control procedure, Documentation Practices, Revision 03. For example, during a review of your firm's Performance Qualification Report, I found your firm made changes to the protocol reporting section without initiating change control and receiving approval to revise the original approved protocol, Qualification Protocol, Version V 3.0. During a review of your firm's Performance Qualification Report, Asset #[illegible], I found your firm made changes to the protocol reporting section and receiving approval to revise the Qualification Protocol, Asset #[illegible]. B. Your firm failed to adequately implement your firm's nonconformance and CAPA Issuance procedure, Revision V.3 dated November 2019, Approved 11/12/2019. For documented deviations, your firm's quality unit made changes within the original protocol without obtaining management approval prior to its implementation and ultimate approval of the performance qualification.

    2. Observation 4

      Compounding essentially copies approved drugs

      Your firm compounds drugs that are essentially a copy within the meaning of sections 503B(a)(5) and 503B(d)(2). Specifically, your firm compounded drugs that are identical to an approved drug that is not on the drug shortage list or are not identical and contain a bulk drug substance that is also a component [illegible], and produces for an individual patient a clinical difference, as determined by the prescribing practitioner, between the compounded drug and the comparable approved drug. Examples of compounded drug products that are essentially a copy: A. Human Chorionic Gonadotropin B. Menotropins Injection C. Leuprolide Acetate Injection D. Pyridoxine HCL Injection. This is a repeat observation.

    3. Observation 5

      Labeling lacks adverse-event info

      The containers of your outsourcing facility's drug products do not include required information under section 503B(a)(10)(B). Specifically, your container labels do not include: a) Information to facilitate adverse event reporting: www.fda.gov/medwatch and 1-800-FDA-1088. Examples of your container labels: 3. Testosterone Cypionate 4. Testosterone Cypionate 5. HCG 12000 IU 6. HCG 6000 IU 7. FSH 1500 IU 8. Menotropins (HMG) 500 IU 9. Ascorbic Acid Preserved 500 mg/ml 10. Leuprolide Acetate 40 MCG/0.2 ml 11. Pyridoxine HCL (Vit B6) 100 mg/ml 12. BCAA 30 ml 15/10/40 13. Taurine 50 mg/ml Injection 14. Omnitrope 5.8 mg Injection 15. Glutathione Preserved 200 mg/ml Injection.

    4. Observation 6

      Adverse event reporting noncompliance

      Your outsourcing facility has not submitted adverse event reports in 2019 in accordance with FDA content and format requirements established through guidance (AE Reporting) under section 310.305 of 21 CFR.

  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete investigations of batch failures

      There is a failure to thoroughly investigate any unexplained discrepancy or failure of a batch, regardless of whether the batch has been distributed, or a failure to expand an investigation to assess other batches that may also be impacted. Specifically, A review of your firm's endotoxin failure, occurring on 10/25/2017 for Lot No. 36029; Tri-Amino CL-Arginine HCL/L-Citrulline/L-Omithine) 100/100/100 mg/mL, revealed that the investigation was incomplete in that: 1) Your firm failed to document a root-cause for the endotoxin failure. 2) Your firm did not implement any corrective actions or preventative measures to assure that future endotoxin failures will not occur when manufacturing this product. 3) Your firm did not evaluate whether other associated lots were impacted. Review of your firm's potency failure, occurring on 10/16/2017 for Lot No. 35979; HCG Lyophilized 3000 IU/vial, revealed that the investigation was incomplete in that: 1) Your firm failed to document a root-cause for the potency failure. 2) Your firm did not implement any corrective actions or preventative measures to assure that future potency failures will not occur when manufacturing this product. 3) Your firm did not evaluate whether other associated lots were impacted.

  7. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    4. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    5. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    Show 2 more citations
    1. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.

    2. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Jul 9, 2026.

  • Inspection ending Nov 14, 2025

    2 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Feb 9, 2026. FDAgent holds no copy that FDA posted.

    1. Jan 6, 2026FDA-FOIA-2026-170Form 483· 1 of 5 sitesRecords released
    2. Dec 9, 2025FDA-FOIA-2025-13774Form 483· 1 of 2 sitesDirected Requester to Publically Available Information
  • Inspection date not given

    3 requests. FDA released records in answer to a request for its Form 483 + EIR on Jul 10, 2026. FDAgent holds no copy that FDA posted.

    1. Jul 9, 2026FDA-FOIA-2026-6585Form 483Records released
    2. Mar 13, 2026FDA-FOIA-2026-2535Form 483 + EIRRecords released
    3. Dec 19, 2025FDA-FOIA-2025-14201EIR· 1 of 2 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.

Show all 12
  • 21 CFR 211.165Testing and release for distribution1 of 3
  • 21 CFR 211.166Stability testing1 of 3
  • 21 CFR 211.180General requirements1 of 3
  • 21 CFR 310.305Records and reports concerning adverse drug experiences on marketed prescription drugs for human use without approved new drug applications1 of 3

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011887629 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011887629. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.