SURGENEX LLC
15444 N 76th St Ste 110, Scottsdale, Arizona, United States
FEI 3011692533
FDA has 2 inspections on file for SURGENEX LLC in Scottsdale, Arizona (FEI 3011692533), from 2021 to 2023. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
FDA published one citation from this inspection, under 21 CFR Part 1271, the rules for human cell and tissue products. It is listed below.
FDA issued a warning letter on (CBER · Office of Biological Products Operations - Division 2). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 2, 2021–2023
- 0 OAI · 0 VAI · 2 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest FY2023
- Warning letters
- · CBER · Office of Biological Products Operations - Division 2 ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood Products1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
In-process HCT/Ps-control
In-process HCT/Ps were not controlled until required inspections, tests, or other verification activities were completed.
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Defined areas of adequate size for operations
The separate or defined areas necessary to prevent contamination or mix-ups are deficient.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Cleaned, sanitized per established schedules
Equipment used for manufacturing HCT/Ps was not maintained according to established schedules.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established, written and followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 7 more citations
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Changes to validated process
A validated process that was changed was not evaluated and revalidated.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Specification description of sample/testing
The specifications for components, drug product containers or closures and labeling are deficient in that they do not include a description of the sampling plan and testing procedures.
Procedures to meet core CTGP
Procedures appropriate to meet core CGTP requirements for all steps that you perform in the manufacture of HCT/Ps were not followed.
Validation & approval--established procedures
Processes with results which could not be fully verified by inspection and tests, were not validated and approved according to established procedures.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Apr 16, 2021NAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-5104Form 483Closed
Inspection date not given
2 requests. FDA released records in answer to a request for its Form 483 + EIR. FDAgent holds no copy that FDA posted.
- Sep 17, 2021FDA-FOIA-2021-6151EIRClosed
- Aug 13, 2021FDA-FOIA-2021-5295Form 483 + EIRReleased in part
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.198Complaint files1 of 2
- 21 CFR 1271.180Procedures1 of 2
Show all 11
- 21 CFR 1271.200Equipment1 of 2
- 21 CFR 1271.220Processing and process controls1 of 2
- 21 CFR 1271.230Process validation1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCBER · Office of Biological Products Operations - Division 2 · BiologicsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011692533 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011692533. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.