Novartis Pharmaceuticals Corporation

220 E Hanover Ave, Morris Plains, New Jersey, United States

FEI 3010353512DUNS 078640106

Company: Novartis Pharmaceuticals Corporation · Linked by exact D-U-N-S match (002147023) in FDA registration data

FDA has 4 inspections on file for Novartis Pharmaceuticals Corporation in Morris Plains, New Jersey (FEI 3010353512), from 2019 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the eight FOIA requests for this site has asked FDA for this inspection's 483.

2 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.113(b) and 21 CFR 211.192.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Novartis Pharmaceuticals Corporation (D-U-N-S 002147023), has registered 19 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2019–2026
0 OAI · 3 VAI · 1 NAI
Inspections with 483 observations shown
3 of 4
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
8 requests, latest Apr 10, 2026
Warning letters
None on file
Import refusals
2 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    2. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent that would alter the safety, identity, strength, quality or purity of the drug product.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

  3. NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    2. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.

    3. Items to cover on annual reviews

      Written procedures are not established for evaluations done at least annually and including provisions for a review of investigations conducted for each drug product.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Eight requests to FDA under the Freedom of Information Act named this site, most recently on Apr 10, 2026.

  • Inspection ending Feb 6, 2026VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on May 27, 2026. FDAgent holds no copy that FDA posted.

    1. Apr 10, 2026FDA-FOIA-2026-3636Form 483· 1 of 5 sitesRecords released
  • Inspection ending Aug 8, 2024VAI

    4 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Nov 8, 2024FDA-FOIA-2024-9913Form 483Closed
    2. Oct 23, 2024FDA-FOIA-2024-9392EIRDenied
    3. Oct 18, 2024FDA-FOIA-2024-9248Form 483Closed
    4. Oct 3, 2024FDA-FOIA-2024-8693Form 483· 1 of 5 sitesClosed
  • Inspection ending Dec 9, 2022NAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Mar 1, 2024FDA-FOIA-2024-2189Form 483Closed
  • Inspection date not given

    2 requests. None of FDA’s log entries for these requests say records were released.

    1. Jan 3, 2024FDA-FOIA-2024-46Form 483No records found
    2. Dec 4, 2023FDA-FOIA-2023-10750Form 483Withdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3010353512, one row per refused product line.

2 refusals from 2025-11-03 to 2025-11-04 · charged AGR RX on 2 · no FDA sample analysis

FDA firm profile
  • 2025-11-04

    SECUKINUMAB58MCP25

    AGR RX 801(d)(1),(2); IMPORTATION RESTRICTED

    Division of West Coast ImportsNUV-3849643-9/20002/1

  • 2025-11-03

    SECUKINUMAB58MCP25

    AGR RX 801(d)(1),(2); IMPORTATION RESTRICTED

    Division of West Coast ImportsNUV-3855286-8/90002/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Novartis Pharmaceuticals CorporationD-U-N-S 002147023

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Novartis Pharmaceuticals Corporation (D-U-N-S 002147023) as the registrant for this site and 19 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Other FEIs recorded as Novartis Pharmaceuticals Corporation

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3010353512 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3010353512. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.