Vital Care Compounder, Inc
115 S 40th Ave, Hattiesburg, Mississippi, United States
FEI 3010241801
FDA has 3 inspections on file for Vital Care Compounder, Inc in Hattiesburg, Mississippi (FEI 3010241801), from 2016 to 2022. The latest ended on and was classified OAI, official action indicated. FDA has issued 3 warning letters under this FEI, the latest on (CDER · Division of Pharmaceutical Quality Operations II).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 8 citations from this inspection. They are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2016–2022
- 3 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 1 posted 483 not matched to an inspection
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.
- FDCA 501(a)(2)(A)
Hazardous drugs, prevention of cross-contamination
You produced hazardous drugs without providing adequate segregation, cleaning of work surfaces and cleaning of utensils to prevent cross-contamination.
- FDCA 501(a)(2)(A)
Personnel habits, contamination
Personnel did not disinfect and change gloves frequently enough to prevent contamination.
- FDCA 501(a)(2)(A)
Disinfecting and cleaning agents, ISO 5 area
Disinfecting agents and cleaning pads and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile.
- FDCA 501(a)(2)(A)
Actionable microbial contamination, ISO 5 area
You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production.
Show 3 more citations
- FDCA 501(a)(2)(A)
Insufficient cycle parameters, heat sterilization of product
The cycle parameters (temperature, pressure and time) used for heat sterilization of product intended to be sterile were not lethal to heat-resistant microorganisms.
- FDCA 501(a)(2)(A)
Personnel contact on container or closure
Personnel used a non-sterile tool on and manually contacted the inner surface of the container or closure.
- FDCA 501(a)(2)(A)
Final/intermediate container and closure, sterile drug product
The final containers/closures used for drug product intended to be sterile were not sterilized and de-pyrogenated.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Show 5 more citations
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size to facilitate cleaning, maintenance, and proper operations.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Valid stability test methods
The written stability program for drug products does not include meaningful and specific test methods.
Cleaning/maintenance records not kept
Records are not kept for the maintenance, sanitizing and inspection of equipment.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
No quality control unit established
OBSERVATION 1 There is no quality control unit. Specifically, 1) Your firm has not established a quality control unit with the responsibility to approve or reject all components, containers, closures, packing material, labeling, and drug products. For example: Your firm produced/distributed a non-patient specific non-sterile oral liquid. This product was identified as C-Chloral Hydrate 100 mg/mL, RX# [illegible]. Per review of the batch record, 10 times the amount of required active ingredient was used, creating a super-potent drug product. This drug product was not rejected by your firm. Also, your firm does not perform potency testing on finished drug products and no retain samples are maintained.
- Observation 2
Aseptic procedures and validations lacking
OBSERVATION 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, 1) On 06/07/2016, we observed an employee aseptically processing patient specific C-VANCOMYCIN SUPER DROPS RX# (b)(6) (eye drops). During the processing we observed the employee, in non-sterile gowning, exiting the clean room and then re-entering without changing gowning materials, including gloves. Also, the employee obtained a bottle containing sterile [illegible] from the prep room. The employee did not wipe down the bottle upon re-entering the clean room, nor did the employee re-sterilize the gloves. 2) On 06/07/2016, we observed a scale, located in the firm's prep room (ISO 8), to contain a white powder residue from previous processing. Also, noted were active ingredients from previous processing in the firm's prep room. 3) On 06/07/2016, the firm's owner gowned in non-sterile gowning items and failed to wipe non-sterile goggles with (b)(4) before entering the firm's ISO 8 prep room. 4) Open trash receptacles were observed in all of the firm's classified areas. Specifically, an open trash receptacle was in close proximity to your ISO 5 Glove Box and your ISO 5 hood located in the clean room. 5) Your firm has not validated the sterilization process (b)(4) autoclave) used for sterilization of rubber stoppers and terminally sterilized finished drug products such as, [illegible] configurations and capacities. According to your firm, (b)(4) are only used (b)(4). 6) Your firm has not validated your (b)(4) sterilization process using (b)(4) to aseptically fill injectable drugs purporting to be sterile. 7) Your firm has not validated your process for the depyrogenation (Dry Heat (b)(4)) of glass vials/glassware used for processing drug products intending to be sterile, such as [illegible] configurations and capacities. According to your firm, (b)(4) are only used (b)(4). This Dry Heat (b)(4) is also used for the (b)(4) sterilization of injectable drug products. 8) Your firm does not perform positive/negative controls on media which is used for sterility testing on finished drug products. The firm's incubators used to incubate media for finished product testing have not been verified. For example, temperatures are not continuously monitored in these incubators. 9) Your firm's media fills do not state (b)(4) (b)(4). Also, the firm's largest batch size would be (b)(4) and the media fills performed by your firm are just for filling (b)(4). 10) Your firm has not performed preservative assay and antimicrobial effectiveness tests on injectable finished drug products contained in multiple dose vials.
Show observations 3 to 13
- Observation 3
Environmental monitoring not performed
OBSERVATION 3 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, 1) Your firm does not monitor viable microbiological contamination in your ISO 7 (clean room) and ISO 5 Hoods during processing. 2) Your firm does not monitor non-viable particulates in your ISO 7 (clean room) and ISO 5 Hoods during processing. 3) Your firm does not monitor microbial contamination on product work surfaces in your ISO 7 (clean room) and ISO 5 Hoods during processing. 4) Your firm does not monitor personnel for microbial contamination during processing. 5) Your firm does not monitor pressure differentials in your ISO 5 Glove Box. Also, your ISO 5 Glove Box does not contain any type of pressure monitoring device.
- Observation 4
Cleaning/disinfection practices inadequate
OBSERVATION 4 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, 1) Your firm does not use a sporicidal cleaning agent in your ISO 5 hood and ISO 5 Glove Box where aseptic processing is performed. 2) Your firm uses non-sterile and low lint wipes to clean in your classified areas. On 06/07/2016, an employee was observed to use these non-sterile wipes in the firm's classified areas (ante room, prep room, clean room, and hood). 3) Your hood in the clean room was observed to have a shattered plastic shield located on the front of the hood, which is unable to be properly cleaned or sanitized. 4) Your hood in the clean room was observed to have a flaking plastic material glued to the bottom of the hood. 5) Your hood in the clean room was observed to have debris on the top of the unit.
- Observation 5
Container-closure systems inadequate
OBSERVATION 5 Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product. Specifically, 1) During this inspection, we observed three injectable drug products to be improperly sealed (crooked metal crimps). Per the firm, the rubber stoppers used for these lots were oversized. These products included Trypan Blue Lot# 391462, Testosterone Cypionate Lot# 382331, and Methylcobalamin Lot# 389279. Containers and closures are not examined upon receipt to ensure they meet specifications for use. 2) During this inspection, we noted finished drug products containing active drug ingredients that are light sensitive being stored in clear glass and plastic containers. Products observed in this condition included Moxifloxacin Lot# 395123 and Betamethasone L/A Lot# 387562.
- Observation 6
Inappropriate personnel gowning
OBSERVATION 6 Clothing of personnel engaged in the manufacturing, processing, and packing of drug products is not appropriate for the duties they perform. Specifically, 1) Non-sterile bunny suits, face masks, shoe covers, and hair covers are used during the production of drug products intended to be sterile.
- Observation 7
Facility construction unsuitable
OBSERVATION 7 Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations. Specifically, 1) Your firm's ISO 5 glove box, which is used for aseptic processing, is located in a non-classified, multipurpose area. This area does not have HEPA filtration. 2) Stains were observed on the HEPA filter located inside the ISO 5 glove box.
- Observation 8
Calibration program not performed
OBSERVATION 8 Routine calibration of equipment is not performed according to a written program designed to assure proper performance. Specifically, There are no records to demonstrate the following equipment has been calibrated for use: 1) The (b)(4) used for (b)(4) for aseptic filling. During this inspection, we noted that the viewing glass on the (b)(4) was damaged in such a way as to block the reading of numerical values. 2) All scales used to weigh ingredients used in processing sterile and non-sterile drug products. Per the firm, a calibration of the scales is carried out with a (b)(4). This (b)(4) had no certification records. This is the only method used by the firm for calibration of the scales (linearity, accuracy, and repeatability are not tested). 3) The thermometers in the incubators used to test environmental and finished product samples. 4) The thermometer used in the depyrogenation (b)(4) used for glass vials/glassware and the terminal sterilization of injectable drug products. 5) The thermometer/pressure gauge in the autoclave used to sterilize rubber stoppers and terminally sterilize injectable drug products.
- Observation 9
Airflow and HEPA filtration issues
OBSERVATION 9 Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, 1) We observed that the firm's only HEPA filter for the clean room was located directly above the ISO 5 hood. 2) On 06/08/2016, it was demonstrated to the firm's primary aseptic processing employee and the firm's owner, using a sheet of paper, how the ISO 7 clean room air was being pulled into the ISO 5 (b)(4) Hood. Also, it was demonstrated with a sheet of paper that in the hood area, where the employee performs aseptic processing, there was no air movement to ensure proper air quality. 3) On 06/07/2016, we observed plastic storage compartments in front of the return HEPA air vent in the firm's ante room. 4) Your firm has no documented diagram or video smoke studies to determine airflow patterns in the firm's classified areas (ISO 8, ISO 7, & ISO 5 Hoods). Also, your firm has no documented evidence that smoke studies were performed under dynamic conditions.
- Observation 10
Sterility and endotoxin testing missing
OBSERVATION 10 Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, 1) Microbial testing is not performed for each lot of drug product purporting to be sterile. Your firm's lots range in volume from (b)(4). Furthermore, you have not validated your microbial testing methods that are performed by your firm. 2) Endotoxin testing is not performed on every lot of injectable finished drug products.
- Observation 11
Stability testing not conducted
OBSERVATION 11 Results of stability testing are not used in determining expiration dates. Specifically, your firm has not conducted any stability testing. Some multiple dose vial products are assigned expiration dates of 18 months for drug products intended to be sterile. Also, your firm produces preservative free products without stability testing. For example, your Methylcobalamin 5,000 mcg/ml has an assigned six month beyond use date.
- Observation 12
No written stability testing program
OBSERVATION 12 There is no written testing program designed to assess the stability characteristics of drug products. Specifically, 1) Your firm has no written protocols for finished drug products and no lots of drug products have been tested for stability.
- Observation 13
No production time limits established
OBSERVATION 13 Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product. Specifically, 1) Your firm has not established any (b)(4) for the sterilized glass vials and rubber stoppers used in processing injectable drug products. Additionally these items (b)(4) [illegible].
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.28Personnel responsibilities1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.166Stability testing1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations II · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010241801 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010241801. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.