Pharmacy Plus, Inc. dba Vital Care Compounder Form 483, October 2022
FDA issued this Form 483 to Pharmacy Plus, Inc. dba Vital Care Compounder in Hattiesburg, Mississippi (FEI 3010241801) at the end of a drug inspection that ended October 13, 2022. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on June 6, 2023.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Dec 20, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Oct 13, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Dec 20, 2022
- 68 days after the inspection
FDA's 8 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.
- FDCA 501(a)(2)(A)
Hazardous drugs, prevention of cross-contamination
You produced hazardous drugs without providing adequate segregation, cleaning of work surfaces and cleaning of utensils to prevent cross-contamination.
- FDCA 501(a)(2)(A)
Personnel habits, contamination
Personnel did not disinfect and change gloves frequently enough to prevent contamination.
- FDCA 501(a)(2)(A)
Disinfecting and cleaning agents, ISO 5 area
Disinfecting agents and cleaning pads and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile.
- FDCA 501(a)(2)(A)
Actionable microbial contamination, ISO 5 area
You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production.
- FDCA 501(a)(2)(A)
Insufficient cycle parameters, heat sterilization of product
The cycle parameters (temperature, pressure and time) used for heat sterilization of product intended to be sterile were not lethal to heat-resistant microorganisms.
- FDCA 501(a)(2)(A)
Personnel contact on container or closure
Personnel used a non-sterile tool on and manually contacted the inner surface of the container or closure.
- FDCA 501(a)(2)(A)
Final/intermediate container and closure, sterile drug product
The final containers/closures used for drug product intended to be sterile were not sterilized and de-pyrogenated.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterJun 6, 2023Pharmacy Plus, Inc., dba Vital Care Compounder warning letter, June 6, 2023CDER · 236 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3010241801, newest first.
- Form 483, May 2019Inspection ended May 16, 2019 · Posted Jul 12, 2019OAI
- Form 483, July 2016Inspection ended Jul 7, 2016 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.