Skip to content

Smart Surgical, Inc

3501 W Elder St Ste 104, Boise, Idaho, United States

FEI 3009744960

FDA has 4 inspections on file for Smart Surgical, Inc in Boise, Idaho (FEI 3009744960), from 2013 to 2021. The latest ended on and was classified NAI, no action indicated. FDA issued a warning letter on (CBER · Office of Biological Products Operations - Division 2).

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

FDA published 11 citations from this inspection: 7 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 4 under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below. One FOIA request has asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
4, 2013–2021
0 OAI · 0 VAI · 4 NAI
Inspections with 483 observations shown
1 of 4
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest FY2023
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.

    2. Determination based on screening and testing

      HCT/P donors were not determined to be eligible based on the results of donor screening and testing.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    4. Process validation procedures

      Procedures to validate and approve processes that cannot be fully verified by inspection and tests were not established and implemented.

    5. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    Show 6 more citations
    1. Donors with risks not determined ineligible

      Donors were not determined to be ineligible that had risk factors or clinical evidence of communicable disease agents.

    2. Acceptance criteria designed to prevent CD

      Incoming HCT/Ps were not accepted, rejected and placed in quarantine based on pre-established criteria designed to prevent communicable disease transmission.

    3. Components withheld from use pending release

      Each lot of components, drug product containers and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    4. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    5. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    6. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

  2. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  3. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  4. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on FY2023. It asked for a Form 483.

  • Inspection ending Mar 5, 2021NAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-5309Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 10 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 4 inspections.

Show all 10

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009744960 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009744960. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.