Skip to content

Neogen Corporation

1847 Mercer Rd Ste A, Lexington, Kentucky, United States

FEI 3009631819DUNS 042125879

FDA has 11 inspections on file for Neogen Corporation in Lexington, Kentucky (FEI 3009631819), from 2009 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 2 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483, and one more for the 483 from a later inspection, ending Mar 6, 2026, that FDA's Data Dashboard doesn't list yet.

FDA issued a warning letter on (CVM). No court action or import refusal is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, labeling and analysis, through Dec 31, 2027. Its registrant is Neogen Corporation (D-U-N-S 069550929).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
11, 2009–2023
0 OAI · 6 VAI · 5 NAI
Inspections with 483 observations shown
6 of 11
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
3 requests, latest May 7, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    2. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

  2. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Complete Test Data

      Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.

    2. Destruction of obsolete labeling

      Obsolete or outdated labels, labeling and packaging materials are not destroyed.

    3. Written program not followed

      The written stability testing program is not followed.

    4. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.

    5. Label storage access limited to authorized personnel

      Access to the storage area for labels and labeling materials is not limited to authorized personnel.

  4. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lab controls established, including changes

      The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit.

    2. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    4. Complete Test Data

      Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.

  5. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lab controls established, including changes

      The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit. Electronic records are used, but they do not meet systems validation and system access limitation requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.

    2. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

  6. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

    2. Review of representative number of batches

      Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    4. Written Procedures Not Followed

      Written procedures are not followed for the testing of components.

  8. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Following/documenting laboratory controls

      Established test procedures and laboratory control mechanisms are not followed and documented at the time of performance.

  9. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  10. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  11. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on May 7, 2026. Each one asked for a Form 483.

  • Inspection ending Mar 6, 2026

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Jun 8, 2026. FDAgent holds no copy that FDA posted.

    1. May 7, 2026FDA-FOIA-2026-4686Form 483· 1 of 5 sitesRecords released
  • Inspection ending Dec 21, 2023VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Dec 8, 2025. FDAgent holds no copy that FDA posted.

    1. Nov 27, 2025FDA-FOIA-2025-13333Form 483Records released
    2. Jan 26, 2024FDA-FOIA-2024-921Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 11 inspections, with how many of them cited each.

Show all 12

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCVM · VeterinaryFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Neogen CorporationD-U-N-S 069550929

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other FEIs recorded as Neogen Corporation

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

  • Neogen CorporationFEI 1120041Lansing, Michigan, United States

    Last inspected 2025-04-07VAI

  • Neogen CorporationFEI 3005038302Lexington, Kentucky, United States

    Last inspected 2016-04-26NAI

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009631819 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009631819. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.