Vita Pharmacy, LLC dba Talon Compounding Pharmacy
2950 Thousand Oaks Dr Ste 25, San Antonio, Texas, United States
FEI 3009192575
FDA has 4 inspections on file for Vita Pharmacy, LLC dba Talon Compounding Pharmacy in San Antonio, Texas (FEI 3009192575), from 2015 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Aug 3, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Eight regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2015–2021
- 3 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- 3 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Cleanroom allows poor air influx
Observation 1 The facility design was observed to allow the influx of poor quality air into a higher classified area. Specifically, A. Your cleanroom design includes the ISO floor into a non-classified/ non differential pressure monitored/controlled area containing dust particulates on the floor. Your pharmacy has identified this area as an [(b) (4)] pharmacy uses this area for storage along with processing area for [(b) (4)] components. The area also has an unrestricted doorway entering your pharmacy's non-sterile hazardous drug processing area. Your [illegible] and lower quality air from entering your classified area identified as an ISO Class 8 which is assessed [(b) (4)] changes made in the cleanroom overall design since the previous FDA inspection. This is a repeat observation. B. No HEPA filter coverage is available for the [illegible] classified area to the ISO 7 Classified cleanrooms which may potentially allow the influx of poor quality air. This is a repeat observation. C. [(15)(4)] doors are designed with no differential pressure in the event of [(b)(4)] dooredges. Your pharmacy document differential pressures in each classified area [(b) (4)]. The [(o)(4)] has are no inter-locking mechanism [(rf!).(1)]. Additionally, there are no [illegible] to detect a change in differential pressure. D. The area outside your pharmacy's modular cleanroom, [illegible] to adequately control and monitor the area as a storage area, containing both an [(fil(4)] doorway which leads to your pharmacy's non-sterile hazardous drug processing area. The area uses a scale on a stainless-steel workbench approximately 3 feet from the unrestricted doorway leading [into the classified area].
- Observation 2
ISO-5 areas not certified dynamically
Observation 2 ISO-5 classified areas were not certified under dynamic conditions. Specifically, during your pharmacy's cleanroom re-certification, unidirectional airflow was not verified under operational (dynamic) conditions where all equipment (mixers and [(b) (4)]) in addition to pharmacy technician simulating drug product processing was in use and being performed in the ISO-5 processing area. Your firm's clean room re-certification reports dated 8/25/2021, 10/23/2020, 8/19/2020, 8/9/2019 and 4/10/2019 were documented as [illegible] simulations and equipment were in use and performed at the time of the documented cleanroom. This is a repeat observation.
Show observation 3
- Observation 3
Improper hazardous drug handling
Observation 3 Your firm handled hazardous drug products without cleaning surfaces and utensils to prevent cross-contamination. Specifically, during a walkthrough of your pharmacy's non-sterile hazardous drug processing area, pharmacy was observed using an air blower underneath [illegible]. A pharmacy technician was in the middle of processing a batch ANAS 0.07MG/B12-1MG/ B7-10MG/ COQ10-100MG/ FINAS 2.5MG 30MG K-CAPS #509 Capsules, Lot #09172021:48, BUD [illegible]. No testing is performed on any processed non-sterile drug products.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Exposure of personnel in aspectic processing
Personnel engaged in aseptic processing were observed with exposed hair.
- FDCA 501(a)(2)(A)
Disinfecting materials, aseptic processing area
Equipment was not disinfected prior to entering the aseptic processing areas.
- FDCA 501(a)(2)(A)
Personnel habits, contamination
Personnel did not disinfect to prevent contamination.
- FDCA 501(a)(2)(A)
Air flow quality, higher classified area
Your facility design allowed the influx of poor quality air into a higher classified area.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
Written program not followed
The written stability testing program is not followed.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Show 5 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Test methods
The accuracy of test methods have not been established.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.
Show 8 more citations
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Buildings not maintained in good state of repair
Buildings used in the processing of a drug product are not maintained in a good state of repair.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.28Personnel responsibilities2 of 3
- 21 CFR 211.42Design and construction features2 of 3
- 21 CFR 211.113Control of microbiological contamination2 of 3
- 21 CFR 211.166Stability testing2 of 3
- 21 CFR 211.167Special testing requirements2 of 3
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.58Maintenance1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
Show all 11
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.111Time limitations on production1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3009192575 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3009192575. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.