Skip to content

Vita Pharmacy, LLC dba Talon Compounding Pharmacy

2950 Thousand Oaks Dr Ste 25, San Antonio, Texas, United States

FEI 3009192575

FDA has 4 inspections on file for Vita Pharmacy, LLC dba Talon Compounding Pharmacy in San Antonio, Texas (FEI 3009192575), from 2015 to 2021. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Aug 3, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Eight regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2015–2021
3 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
4 of 4
3 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
4 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Cleanroom allows poor air influx

      Observation 1 The facility design was observed to allow the influx of poor quality air into a higher classified area. Specifically, A. Your cleanroom design includes the ISO floor into a non-classified/ non differential pressure monitored/controlled area containing dust particulates on the floor. Your pharmacy has identified this area as an [(b) (4)] pharmacy uses this area for storage along with processing area for [(b) (4)] components. The area also has an unrestricted doorway entering your pharmacy's non-sterile hazardous drug processing area. Your [illegible] and lower quality air from entering your classified area identified as an ISO Class 8 which is assessed [(b) (4)] changes made in the cleanroom overall design since the previous FDA inspection. This is a repeat observation. B. No HEPA filter coverage is available for the [illegible] classified area to the ISO 7 Classified cleanrooms which may potentially allow the influx of poor quality air. This is a repeat observation. C. [(15)(4)] doors are designed with no differential pressure in the event of [(b)(4)] dooredges. Your pharmacy document differential pressures in each classified area [(b) (4)]. The [(o)(4)] has are no inter-locking mechanism [(rf!).(1)]. Additionally, there are no [illegible] to detect a change in differential pressure. D. The area outside your pharmacy's modular cleanroom, [illegible] to adequately control and monitor the area as a storage area, containing both an [(fil(4)] doorway which leads to your pharmacy's non-sterile hazardous drug processing area. The area uses a scale on a stainless-steel workbench approximately 3 feet from the unrestricted doorway leading [into the classified area].

    2. Observation 2

      ISO-5 areas not certified dynamically

      Observation 2 ISO-5 classified areas were not certified under dynamic conditions. Specifically, during your pharmacy's cleanroom re-certification, unidirectional airflow was not verified under operational (dynamic) conditions where all equipment (mixers and [(b) (4)]) in addition to pharmacy technician simulating drug product processing was in use and being performed in the ISO-5 processing area. Your firm's clean room re-certification reports dated 8/25/2021, 10/23/2020, 8/19/2020, 8/9/2019 and 4/10/2019 were documented as [illegible] simulations and equipment were in use and performed at the time of the documented cleanroom. This is a repeat observation.

    Show observation 3
    1. Observation 3

      Improper hazardous drug handling

      Observation 3 Your firm handled hazardous drug products without cleaning surfaces and utensils to prevent cross-contamination. Specifically, during a walkthrough of your pharmacy's non-sterile hazardous drug processing area, pharmacy was observed using an air blower underneath [illegible]. A pharmacy technician was in the middle of processing a batch ANAS 0.07MG/B12-1MG/ B7-10MG/ COQ10-100MG/ FINAS 2.5MG 30MG K-CAPS #509 Capsules, Lot #09172021:48, BUD [illegible]. No testing is performed on any processed non-sterile drug products.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Exposure of personnel in aspectic processing

      Personnel engaged in aseptic processing were observed with exposed hair.

    2. FDCA 501(a)(2)(A)

      Disinfecting materials, aseptic processing area

      Equipment was not disinfected prior to entering the aseptic processing areas.

    3. FDCA 501(a)(2)(A)

      Personnel habits, contamination

      Personnel did not disinfect to prevent contamination.

    4. FDCA 501(a)(2)(A)

      Air flow quality, higher classified area

      Your facility design allowed the influx of poor quality air into a higher classified area.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.

    2. Written program not followed

      The written stability testing program is not followed.

    3. Clothing appropriate for duties performed

      Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.

    4. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    5. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    Show 5 more citations
    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    4. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  6. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.

    2. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    4. Test methods

      The accuracy of test methods have not been established.

    5. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

    Show 8 more citations
    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    3. Clothing appropriate for duties performed

      Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.

    4. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    5. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components at all times in a manner to prevent contamination.

    6. Buildings not maintained in good state of repair

      Buildings used in the processing of a drug product are not maintained in a good state of repair.

    7. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy.

    8. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.

Show all 11

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009192575 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009192575. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.