American Pharmacy of Illinois, Inc. dba Alwan Pharmacy and Compounding Center
311 N Western Ave, Peoria, Illinois, United States
FEI 3008688061
FDA has 3 inspections on file for American Pharmacy of Illinois, Inc. dba Alwan Pharmacy and Compounding Center in Peoria, Illinois (FEI 3008688061), from 2010 to 2018. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Aug 30, 2018 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 5 citations from this inspection. They are listed below.
The most recent OAI inspection ended on Oct 28, 2015. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2010–2018
- 1 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 3
- 3 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Use of non-pharmaceutical grade components
You used a non-pharmaceutical grade component in the formulation of a drug product.
- FDCA 501(a)(2)(A)
Disinfecting materials, aseptic processing area
Materials or supplies were not disinfected prior to entering the aseptic processing areas.
- FDCA 501(a)(2)(A)
Non-sterilized and non-depyrogenated, sterile drug
Non-sterilized and Non-depyrogenated equipment was used in sterile drug production.
- FDCA 501(a)(2)(A)
Air flow quality, higher classified area
Your facility design allowed the influx of poor quality air into a higher classified area.
- FDCA 501(a)(2)(A)
Highly potent drugs, prevention of cross-contamination
You produced highly potent drugs without providing adequate cleaning of utensils to prevent cross-contamination.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance16 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Show 11 more citations
Defined areas of adequate size for operations
The control systems necessary to prevent contamination or mix-ups are deficient.
Training , Education , Experience overall
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Equipment for Environmental Control
Equipment for adequate control over air pressure, micro-organisms, dust, humidity, and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.28Personnel responsibilities1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 2
- 21 CFR 211.56Sanitation1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.111Time limitations on production1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
Show all 11
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.167Special testing requirements1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008688061 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008688061. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.